IAI SP-20000M-PMCL User Manual page 77

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)
TapGeometry: 1X2-1Y
Camera Link
Binning
Clock
Vertical
1 (Off)
80MHz
2 (On)
1 (Off)
60MHz
2 (On)
Minimum Trigger Interval calculation formula [Unit: us]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 521
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) ×2618.54) - 2618.54 +
([Width]÷2))÷80MHz×10^6)+667
(2) If [Exposure Time] value is more than 1Frame = 521 + [Exposure Time]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 521
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) ×5237.09) - 2560 +
([Width]÷2))÷80MHz×10^6)+667
(2) If [Exposure Time] valueis more than 1Frame = 521 + [Exposure Time]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 696
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) ×2637.25) - 2637.25 +
([Width]÷2))÷60MHz×10^6)+892
(2) If [Exposure Time] valueis more than 1Frame = 696 + [Exposure Time]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 696
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) ×5274.49) - 2560 +
([Width]÷2))÷60MHz×10^6)+892
(2) If [Exposure Time] value is more than 1Frame = 696 + [Exposure Time]
EPS Trigger / Trigger Overlap = Readout
- 77 -