Pulse Generator Clear Sync Mode
Set the count clear method for the selected pulse generator.
In case of Async Mode, if the clear signal is input during the length setting value, the counter will stop
counting according to the clear signal input. In case of Sync Mode, if the clear signal is input during the
length setting value, the counter will continue to count until the end of the length setting value and then
clear the count. Both modes clear the repeat count when the counter is cleared.
Pulse Generator Clear Source
The following clear source can be selected as the pulse generator clear signal.
0:Low, 1:High, 3: FrameTriggerWait, 4: FrameActive, 5: ExposureActive, 6: Fval, 8: PulseGenerator0, 9:
l
PulseGenerator1, 10: PulseGenerator2, 11: PulseGenerator3, 12: TTL_In1, 13: CL_CC1_In, 14: Nand0,
15: Nand1, 16: TTL_In2, 17: LVDS_In
Note: The pulse generator output cannot be used as the clear input to the same pulse generator.
Refer to
"Input and Output Matrix
Table".