CM-140GE / -RA/-UV / CB-140GE / -RA
Full Scan
1/2 Partial
1055 L
The conditions for this table are that shutter speed should be set the same for all sequences. If
the shutter speed is different, the difference of exposure time should be added.
recommended to set the exposure time in order of the shortest to the longest one.
Do not input the trigger just after the sequence is reset. It requires at least 500ms delay.
In sequential mode, the exposure should be adjusted so that the LVAL a-sync mode can always
be functioned.
8.5.5 Delayed Readout mode (Pre-Select trigger and pulse width control trigger)
This mode can be used to delay the transmission of a captured image. When several cameras are
triggered simultaneously and connected to the same GigE interface, it allows the cameras to be
read out in sequence, preventing congestion.
The image data is not transmitted directly by the trigger 0 and it is stored in the memory located
at Ethernet Interface. By the falling edge of the trigger 1, the image data is output.
Trigger 0
CCD Photodiode
CCD Transfer gate
GigE memery
Trigger 1
Ethernet output
Example of setting
0xA040
Delayed Readout (0x11)
0xB060
Trigger 0 select, e.g. 0x04 OPT IN 1
0xB064
Trigger 1 select, e.g. 0x05 OPT IN 2
For the details of Registers, please refer Camera Register Map which is included in the SDK.
2/3 Partial
821 L
705 L
Exposure
1/4 Partial
531 L
CCD output
Store in the
GigE memory
- 44 -
1/8 Partial
1/2 V Binning
445 L
530 L
Output from
GigE
It is