Tap Geometry: 1X4-1Y - IAI SP-20000M-PMCL User Manual

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)

Tap Geometry: 1X4-1Y

Item
1Line Control Start Exposure
Time value [Unit: us]
1Line Control End Exposure
Time value [Unit: us]
When overlapped, Exposure
Time effective step value [Unit:
us/step]
Exposure Start Position [Unit:
Line]
Exposure Time Max value
Camera
Binning
Continuous trigger readout / exposure overlapped period Exposure
Link Pixel
Vertical
Clock
ROUND([Frame Rate (Time)] - ((([Height]×1309.27) + 24931 - 1309.27 +
80MHz
([Width]÷4) ÷[Camera Link Clock Frequency:80MHz]×(10^6)))
1 (Off)
ROUND([Frame Rate (Time)] - ((([Height]×1318.61) + 25111 - 1318.61+
60MHz
([Width]÷4)) ÷[Camera Link Clock Frequency:60MHz]×(10^6)))
ROUND([Frame Rate (Time)] - ((([Height]×2618.53) + 24931 - 1280 +
80MHz
([Width]÷4)) ÷[Camera Link Clock Frequency:80MHz]×(10^6)))
2 (On)
ROUND([Frame Rate (Time)] - ((([Height]×2637.23) + 25111−1280 +
60MHz
([Width]÷4)) ÷[Camera Link Clock Frequency:60MHz]×(10^6)))
ROUND([Frame Rate (Time)] - (24931÷[Camera Link Clock
80MHz
Frequency:80MHz]×(10^6))
1 (Off),
2 (On)
ROUND([Frame Rate (Time)] - (25111÷[Camera Link Clock
60MHz
Frequency:60MHz]×(10^6))
80MHz
ROUNDDOWN(1309.27÷[Camera Link Clock Frequency]×10^6)
1 (Off)
60MHz
ROUNDDOWN(1318.61÷[Camera Link Clock Frequency]×10^6)
80MHz
ROUNDDOWN(2618.53÷[Camera Link Clock Frequency])×10^6÷2)
2 (On)
60MHz
ROUNDDOWN(2637.23÷[Camera Link Clock Frequency])×10^6÷2)
[Height] - 1 - (ROUNDOWN( ( [Exposure Time] - [1Line Control Start
80MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:80MHz]÷1309.27))
1 (Off)
[Height] - 1 - (ROUNDOWN( ( [Exposure Time] - [1Line Control Start
60MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:80MHz]÷1318.61))
[Height] - 0.5 - (ROUNDOWN( ( [Exposure Time] - [1Line Control Start
80MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:80MHz]÷2618.53)÷2)
2 (On)
[Height] - 0.5 - (ROUNDOWN( ( [Exposure Time] - [1Line Control Start
60MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:60MHz]÷2637.23)÷2)
ROUNDDOWN([Frame Rate (Time)] - (20600÷[Camera Link Clock
80MHz
Frequency:80MHz]×10^6 ))
1 (Off),
2 (On)
ROUNDDOWN([Frame Rate (Time)] - (20600÷[Camera Link Clock
60MHz
Frequency:60MHz]×10^6 ))
Time value calculation formula
- 65 -
Main Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-20000c-pmcl

Table of Contents