SP-20000-PMCL User Manual (Ver. 3.1)
Save the User Settings
1. Stop image acquisition. Settings can only be saved when image acquisition on the camera is stopped.
2. Specify the storage location (UserSet1 - UserSet3) using the UserSetSave command and save the
current camera settings.
Item
UserSetSave
Load the User Settings
1. Stop image acquisition. User settings can only be loaded when image capture on the camera is stopped.
2. Specify the storage location (UserSet1 - UserSet3) using the UserSetLoad command and read the
settings of the camera.
Note: When selecting Default, the factory settings are loaded.
Item
UserSetLoad
Short ASCII
Values
Command
1: User1
SA
2: User2
3: User3
Short ASCII
Command
0: Default (Default)
1: User1
LD
2: User2
3: User3
SA= Param. <CR><LF>
SA?<CR><LF>
Values
LD= Param. <CR><LF>
LD?<CR><LF>