GO-2400MC-PGE-1 | GO-2401MC-PGE-1 | User Manual (Ver. 1.0)
Trigger Control
Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
Trigger Selector
FrameStart
AcquisitionStart
AcquisitionEnd
AcquisitionTransferStart
Note: The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
Scanning Range
Full
ROI 2/3 (Height=810) 13.637
ROI 1/2 (Height=608) 10.236
ROI 1/4 (Height=304) 5.118
ROI 1/8 (Height=152) 2.559
Binning Vertical 2
(Monochrome models
only)
The above table indicates the shortest trigger periods for when Trigger OverLap is set to Readout.
When Trigger OverLap is set to Off, the exposure time is added to the period.
AcquisitionControl
Start exposure in response to the external trigger signal input. Select this to perform
exposure control using external triggers.
Start image acquisition in response to the external trigger signal input.
Stop image acquisition in response to the external trigger signal input.
Output acquired images at a specified timing in response to an external trigger
signal input. (Up to 7 frames for 8-bit, and up to 3 frames for 10-/12-bit.)
"Configure Exposure and External Trigger
8 bit (ms)
GO-2400-
GO-2401-
PGE-1
PGE-1
20.472
24.360
16.486
12.569
6.673
3.725
15.632
24.360
Description
Shortest Period of Trigger
10 bit/12 bit Packed (ms)
GO-2400-
GO-2401-
PGE-1
PGE-1
30.707
30.707
20.608
20.608
15.711
15.711
8.341
8.341
4.656
4.656
30.450
30.450
- 47 -
Main Functions
Settings".
10 bit/12 bit (ms)
GO-2400-
GO-2401-
PGE-1
PGE-1
40.943
40.943
27.273
27.273
20.472
20.472
10.236
10.236
5.118
5.118
30.450
30.450