Control Via External Triggers - IAI SW-4000M-PMCL User Manual

Monochrome line scan camera
Table of Contents

Advertisement

17 for additional details.
Also, [Binning Vertical] must be set independently in each operation mode.
Configuring the Output Format
Configure the pixel format for images.
Image Format Control

Control via External Triggers

When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Trigger Selector (trigger operation)
Trigger Mode
Trigger Source (trigger signal source)
Trigger Activation (trigger polarity)
Exposure Mode
Exposure Time
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
3
Set [Trigger Mode] to [On].
4
If necessary, change the [Trigger Source], and [Trigger Activation] settings.
When Controlling the Exposure Time Using the Pulse Width of the Trigger Input Signal
Configure the settings as follows.
Trigger Selector (trigger operation)
Trigger Mode
Trigger Source (trigger signal source)
Trigger Activation (trigger polarity)
Exposure Mode
1
Set [Trigger Mode] to [On] .
Item
Pixel Format
Item
Item
— 15 —
Default value
mono8 (8-bit monochrome)
Setting value / selectable range
Line Start
On
Any
Rising Edge (rising edge of input signal), Falling Edge (falling
edge of input signal)
Timed (control via exposure time)
Varies depending on the Tap Geometry and CL Pixel Clock
settings.
Setting value / selectable range
Line Start
On
Any
Level High (high-level duration), Level Low (low-level
duration)
Trigger Width (control via trigger width)
SW-4000M-PMCL

Advertisement

Table of Contents
loading

Table of Contents