LUT (Lookup Table)

Related Setting Items:
This function can be used to convert the input to the desired output characteristics. The Look-Up Table
(LUT) has 256 points for setup. The output level can be created by multiplying the gain data by the
input level.
To Use the LUT function
Configure the settings as follows.
Setting Value /
Item
Selectable Range
JAI LUT
LUT
Mode
LUT
0 ~ 255
Index
LUT
0 ~ 4095
Value
LUT Control
Can be selected from OFF, Gamma or LUT Table.
This camera has a 256-point Lookup Table, meaning the index points are
treated like an 8bit image with 0 representing a full black pixel and 255
representing a full white pixel.
LUT values range from 0 at the lowest to 4095 at the highest. Linear
interpolation is used to calculate LUT values between the index points.
Output Data = Video IN x LUT data