SP-20000-PMCL User Manual (Ver. 3.1)
Pulse Generator Length
Set the counter up value for the selected pulse generator. If Repeat Count value is "0", and if Pulse
Generator Clear signal is not input, the pulse generator generates the pulse repeatedly until reaching
this counter up value.
Pulse Generator Start Point
Set the active output start count value for the selected pulse generator. However, please note that a
maximum 1 clock jitter for the clock which is divided in the clock pre-scaler can occur.
Pulse Generator End Point
Set the active output ending count value for the selected pulse generator.
Pulse Generator Repeat Count
Set the repeating number of the pulse for the selected pulse generator. After Trigger Clear signal is
input, the pulse generator starts the count set in Repeat Count. Accordingly, an active pulse which has
a start point and end point can be output repeatedly. However, if Repeat Count is set to "0", it works as
free-running counter.
Pulse Generator Clear Activation
Set the clear conditions of clear count pulse for the selected pulse generator.
- 36 -