Sequence Roi Setting Parameters - IAI SP-20000M-PMCL User Manual

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)
one.
The sequence must start with Index 0. After Index 0 is executed, the sequence proceeds to the next
l
setting index.
In this mode, while the previous trigger operation (Index table) is activating, the next trigger cannot be
overlapped. Sequence index table must be through index 0 and after index 0 is performed, the next
index can be operated.

Sequence ROI Setting Parameters

Setting parameters for Sequence ROI are as follows. (The Default shows the default value for Index 1
~ 10, except Sequence ROI Next Index)
Item
Default
Sequence
In Sequence ROI Index Selector, Index 1 to 10 can be selected. Sequence ROI – Width, Height, Offset X,
ROI Index
-
Offset Y, Gain Selector - Gain/Red/Blue, Exposure Time, Black Level, Binning Horizontal, Binning Vertical,
Selector
LUT Enable, Frame Count, Next Index for the selected index are displayed.
Sequence
This can set how many times the selected index is repeated. This is applied to each index. Triggers are input
ROI Frame
1
according to numbers set in Frame Count and index is repeated and moves to the next index. Therefore, the
Count
same number of triggers as Frame Count must be input.
Sequence
The number of the index that will follow the current index can be set. If [Video Send Mode] is set to "Trigger
ROI Next
Index 0
Sequence" and the trigger pulse is input in EPS trigger, the sequence is executed from index 0.
Index
Sequence
Set the width of sequence ROI. The setting range is 8 to 5120 Pixels. Rules for setting area and step number
5120
ROI Width
are the same as the normal ROI mode set by [Video Send Mode] ="Normal".
Sequence
Set the height of sequence ROI. The setting range is 2 to 3840 lines. Rules for setting area and step number
3840
ROI Height
are the same as the normal ROI mode set by [Video Send Mode] ="Normal".
Set Offset X of sequence ROI.
Sequence
0
ROI Offset X
The limitations of step number and other factors are the same as the normal ROI mode set by [Video Send
Mode] ="Normal".
Set Offset Y of sequence ROI.
Sequence
0
ROI Offset Y
The limitations of step number and other factors are the same as the normal ROI mode set by [Video Send
Mode] ="Normal".
Sequence ROI Binning Horizontal =1 (Off): Setting range is 0 to (5120 - [Sequence ROI Width])
l
Sequence ROI Binning Horizontal =2 (On): Setting range is 0 to (2560 - [Sequence ROI Width])
l
Sequence ROI Binning Vertical =1 (Off): Setting range is 0 to (3840 - [Sequence ROI Height])
l
Sequence ROI Binning Vertical =2 (On): Setting range is 0 to (1920 - [Sequence ROI Height])
l
Description
- 99 -
Main Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-20000c-pmcl

Table of Contents