SP-20000-PMCL User Manual (Ver. 3.1)
Minimum Trigger Interval Calculation Formula (Trigger Overlap = Readout,
TriggerWidth Mode)
TapGeometry: 1X8-1Y
Camera Link
Binning
Clock
Vertical
1 (Off)
80MHz
2 (On)
1 (Off)
60MHz
2 (On)
Note: When Trigger Overlap is set to Readout, if the trigger interval is set at more than the period
specified in the above table or Trigger Pulse width, the exposure operation may not work properly
and the video image may be deteriorated.
Minimum Trigger Interval calculation formula [Unit: us]
At the condition of [Trigger Pulse Width] ≦ [Trigger Period: us] - 266us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) × 654.63) - 654.63 +
([Width]÷8))÷80MHz×10^6)+331
(2) If [Trigger Pulse Width] is more than 1Frame = 266 + [Trigger Pulse Width]
At the condition of [Trigger Pulse Width] ≦ [Trigger Period: us] - 266us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) ×1309.27) - 640 +
([Width]÷8))÷80MHz×10^6)+331
(2) If [Trigger Pulse Width] is more than 1Frame = 266 + [Trigger Pulse Width]
At the condition of [Trigger Pulse Width] ≦ [Trigger Period: us] - 353us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) × 659.31) - 659.31 +
([Width]÷8))÷60MHz×10^6)+441
(2) If [Trigger Pulse Width] is more than 1Frame = 353 + [Trigger Pulse Width]
At the condition of [Trigger Pulse Width] ≦ [Trigger Period: us] - 353us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) ×1318.61) - 1318.61 +
([Width]÷8))÷60MHz×10^6)+441
(2) If [Trigger Pulse Width] is more than 1Frame = 353 + [Trigger Pulse Width]
Trigger Width/ Trigger Overlap = Readout
- 89 -
Main Functions