⑤ ⑥ Camera Link Connector 2 & 1
⑤ Camera Link Connector 2: Digital video output (Medium and Full configuration)
⑥ Camera Link Connector 1: Digital video output (Base, Medium and Full config.)
Type: 26-pin Mini Camera Link connector (Honda HDR-EC26FYTG2-SL+)
Input
Pin No.
Output
1, 26
2 (-), 15 (+)
Out
3 (-), 16 (+)
Out
4 (-), 17 (+)
Out
5 (-), 18 (+)
Out
6 (-), 19 (+)
Out
7 (+), 20 (-)
In
8 (-), 21 (+)
Out
9 (-), 22 (+)
In
10 (+), 23 (-)
CC2 (Reserved)
11, 24
12, 25
13, 14
Caution:
This camera supports PoCL, but since the power consumption of the camera exceeds
the allowable power consumption of a single cable, please connect two cables when using the
camera with PoCL.
⑦ ⑧ Mounting Holes (M3)
Use these holes when attaching an MP-42 tripod adapter plate (optional) or mounting the camera
directly to a wall or other structural system.
⑦ M3, Depth 5mm
⑧ M3, Depth 3mm
Signal
Description
Power
Power
X_OUT0
Data out
X_OUT1
Data out
X_OUT2
Data out
X_Clk
CL Clock
X_OUT3
Data output
SerTC (RxD)
LVDS Serial Control
SerTFG (TxD)
CC1 (Trigger)
JAI standard trigger
N.C
N.C
Shield
Power return
Input
Pin
Output
1, 26
2 (-), 15 (+)
3 (-), 16 (+)
4 (-), 17 (+)
5 (-), 18 (+)
6 (-), 19 (+)
7, 20
8 (-), 21 (+)
9 (-), 22 (+)
10 (-), 23 (+)
11 (-), 24 (+)
12 (+), 25 (-)
13, 14
- 18 -
Parts Identification
Signal
Description
Power
Out
Y_OUT0
Out
Y_OUT1
Out
Y_OUT2
Out
Y_Clk
Out
Y_OUT3
N.C
Out
Z_OUT0
Out
Z_OUT1
Out
Z_OUT2
Out
Z_Clk
Out
Z_OUT3
Shield
Power Return
Power
Data out
Data out
Data out
CL Clock
Data out
Data out
Data out
Data out
CL Clock
Data out