Data Area, Acquisition, Gamma, Temperature
Name
CurrentAreaNoRequest
AcquisitionFrameTime
Related Topic:
Acquisition
Control (Change the Frame
Rate)
GammaSelector
Related Topic:
Gamma
Function
Temperature
Short
Access
Min ~ Max Default
ASCII
0: Factory
area
1: User 1
area
R/O
EA
2: User 2
area
3: User 3
area
1 ~
R/W
ART
8000000
0(γ=1) ~
8 (γ=0.45)
R/W
GMA
~
15
(γ=TBD)
R/O
TMP0
-
- 134 -
EA?<CR><LF>
Display the currently configured Use Set Selector
0
status. (Start up with the state saved to this area.)
The camera returns the latest used DATA AREA.
ART=[Param.]<CR><LF>
ART?<CR><LF>
32000
Set the Acquisition Frame Time. Maximum value is
calculated depending on Height and Offset Y settings
GMA=[Param.]<CR><LF>
GMA?<CR><LF>
8
Set the gamma value.
TMP0?<CR><LF>
-
Display the internal temperature (C°) of the camera.