Calculation For The Period Which The Exposure Time Is Overlapped With Previous Trigger In Continuous Trigger Mode; Tap Geometry: 1X8-1Y - IAI SP-20000M-PMCL User Manual

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)
Calculation for the Period Which the Exposure Time is Over-
lapped with Previous Trigger in Continuous Trigger Mode

Tap Geometry: 1X8-1Y

Exposure Start Position [Unit:
Line]
1Line Control Start Exposure
Time value [Unit: us]
1Line Control End Exposure
Time value [Unit: us]
When overlapped, Exposure
Time effective step value [Unit:
us/step]
Camera
Binning
Continuous trigger readout / exposure overlapped period Exposure
Link Pixel
Vertical
Clock
ROUND([Frame Rate (Time)] - ((([Height]×654.63)+24901 -654.63+
80MHz
([Width]÷8))
÷ [Camera Link Clock Frequency:80MHz]×(10^6)))
1 (Off)
ROUND([Frame Rate (Time)] - ((([Height]×659.31)+25109 -654.63+
60MHz
([Width]÷8))
÷ [Camera Link Clock Frequency:60MHz]×(10^6)))
ROUND([Frame Rate (Time)] - ((([Height]×1309.27)+24901 -640+
80MHz
([Width]÷8))
÷ [Camera Link Clock Frequency:80MHz]×(10^6)))
2 (On)
ROUND([Frame Rate (Time)] - ((([Height]×1318.61)+25109 -640+
60MHz
([Width]÷8))
÷ [Camera Link Clock Frequency:60MHz]×(10^6)))
ROUND([Frame Rate (Time)] - (24901÷[Camera Link Clock
80MHz
Frequency:80MHz]×(10^6))
1 (Off),
2 (On)
ROUND([Frame Rate (Time)] - (25109÷[Camera Link Clock
60MHz
Frequency:60MHz]×(10^6))
80MHz
ROUNDDOWN(654.63÷[Camera Link Clock Frequency:80MHz]×10^6)
1 (Off)
60MHz
ROUNDDOWN(659.31÷[Camera Link Clock Frequency:60MHz]×10^6)
80MHz
ROUNDDOWN(1309.27÷[Camera Link Clock Frequency:80MHz]×10^6÷ 2)
2 (On)
60MHz
ROUNDDOWN(1318.61÷[Camera Link Clock Frequency:60MHz]×10^6÷ 2)
Time value calculation formula