Calculation Formula for the Minimum Trigger Interval (Trigger Overlap =
Readout, Timed Mode)
TapGeometry: 1X8-1Y
Camera Link
Binning
Clock
Vertical
1 (Off)
80MHz
2 (On)
1 (Off)
60MHz
2 (On)
Note: When Trigger Overlap is set to Readout, if the trigger interval is set more than the period
specified in the above table, the exposure operation may not be activated, and the video may be
disturbed.
Minimum Trigger Interval calculation formula [Unit: us]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 266
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) × 654.63) - 654.63 +
([Width]÷8))÷80MHz×10^6)+331
2) If [Exposure Time] value is more than 1Frame = 266 + [Exposure Time]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 266
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) ×1309.27) - 640 +
([Width]÷8))÷80MHz×10^6)+331
(2) If [Exposure Time] valueis more than 1Frame = 266 + [Exposure Time]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 353
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) × 659.31) - 659.31 +
([Width]÷8))÷60MHz×10^6)+441
(2) If [Exposure Time] value is more than 1Frame = 353 + [Exposure Time]
At the condition of [Exposure Time Max] ≦ [Trigger Period] - 353
(1) If [Exposure Time] value is less than 1Frame = ROUND(((([Height] + 1) ×1318.61) - 1318.61 +
([Width]÷8))÷60MHz×10^6)+441
(2) If [Exposure Time] value is more than 1Frame = 353 + [Exposure Time]
EPS Trigger / Trigger Overlap = Readout