Trigger Activation
This command can select how to activate the trigger.
Rising edge: At the rising edge of the pulse, the trigger is activated.
l
Falling edge: At the falling edge of the pulse, the trigger is activated.
l
Level High: During the high level of trigger, the accumulation is activated
l
Level Low: During the low level of trigger, the accumulation is activated
l
Note: If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Camera Settings
Trigger
Trigger
Selector
Mode
On
Frame Start
On
On
Trigger Overlap
This function defines whether or not a trigger pulse can be accepted while data is being read out.
OFF: The trigger pulse is not accepted during CMOS readout.
l
Read Out: The trigger pulse can be accepted during CMOS readout.
l
Exposure
Trigger
Mode
Option
Timed
Off
Trigger Width
Off
Timed
PIV
JAI Custom Trigger Mode
Name
EPS Trigger
PWC Trigger
PIV Trigger