Trigger Control - IAI GOX-5105M-PGE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Table of Contents

Advertisement

GOX-5105MC-PGE | GOX-8105MC-PGE | GOX-12405MC-PGE | GOX-16205MC-PGE | GOX-20405MC-PGE | GOX-24505MC-PGE

Trigger Control

Related Setting Items:
The camera allows the following controls to be performed via external trigger signals.
TriggerSelector
AcquisitionStart
AcquisitionEnd
FrameStart
AcquisitionTransferStart
Notes:
The settings for exposure control and triggers are related to each other. Be sure to configure
l
the settings described in
You can delay when exposure actually starts after a trigger is received for a specific amount
l
of time by configuring TriggerDelay.
Select the trigger type with TriggerSelector, and set the following items for each trigger.
TriggerMode
Switch enable or disable.
Select the source signal (PulseGenerator0-3, UserOutput0-3, Action0-3, Software, Line5
Opt In, Nand0 Out, Nand1 Out).
TriggerSource
TriggerActivation Sets the polarity of the trigger signal.
AcquisitionControl
Start image acquisition in response to the external trigger signal input.
Stop image acquisition in response to the external trigger signal input.
Start capturing a one-frame image in response to the external trigger signal input.
Select this to perform exposure control using external triggers.
Note: The FrameStart Trigger can only be used when the
setting is set to Timed.
Start output of acquired image data in response to external trigger signal input
(delayed readout).
Note: See the
Burst Trigger Mode
acquired on each model.
Exposure
Note: Trigger can be executed by TriggerSoftware[TriggerSelector] command only
when Software is set.
User Manual (Ver. Preliminary) - Main Functions
Description
topic for the number of frames that can be
Mode.
- 41 -
Exposure Mode