SP-20000-PMCL User Manual (Ver. 3.1)
TriggerWidth Mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer exposure times
are supported. Additional settings determine if the trigger pulse can be accepted during the exposure
period.
Basic settings to use this mode
Trigger Mode = ON
l
Exposure Mode = Trigger Width
l
Minimum trigger interval (Trigger Overlap = Readout)
Readout Mode
≧ 31.761ms ≧ 42.648ms ≧ 63.200ms ≧ 84.864ms ≧ 126.389ms ≧ 169.719ms
Full
≧ 21.287ms ≧ 28.582ms ≧ 42.252ms ≧ 56.734ms ≧ 84.492ms
ROI Center 2/3
ROI Center 1/2
≧ 16.050ms ≧ 21.550ms ≧ 31.777ms ≧ 42.669ms ≧ 63.544ms
≧ 8.195ms
ROI Center 1/4
≧ 4.267ms
ROI Center 1/8
V Binning ON*
≧ 31.770ms ≧ 42.658ms ≧ 63.216ms ≧ 84.887ms ≧ 126.423ms ≧ 169.764ms
(Full)
*Monochrome model only
Note: If Trigger Overlap is OFF, the accumulation time is added to the above table.
1x8 – 1Y
80 MHz
60 MHz
≧ 11.001ms ≧ 16.066ms ≧ 21.571ms ≧ 32.121ms
≧ 5.726ms
1x4 – 1Y
80 MHz
60 MHz
≧ 8.211ms
≧ 11.022ms ≧ 16.410ms
- 84 -
Main Functions
1X2 – 1Y
80 MHz
60 MHz
≧ 113.457ms
≧ 85.327ms
≧ 43.131ms
≧ 22.033ms