IAI SP-20000M-PMCL User Manual page 93

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)
Notes:
The exposure time for the first frame (te1) can be set by [Exposure Time].
l
The second exposure time (te2) varies by ROI setting and Binning setting but is not affected by
l
[Exposure Time] setting.
PIV Trigger Mode Specifications (1X8 – 1Y)
Description
Exposure Beginning
td
delay
First exposure time
te1
period
itf
Inter framing time
Second exposure
te2
time
Camera Link Pixel Clock = 80MHz
430 ns~470 ns
10us ~ ≒ 1 Frame ([Height]=3840 :
31737us Max) = [Exposure Time Settings]
312 us
≒ 1 frame
(1) V-Binning Off
= ([Height]×654.63÷80MHz) + 131 us
(2) V-Binning On
= ([Height]×1309.27÷80MHz) + 131 us
Camera Link Pixel Clock = 60MHz
500 ns ~ 540 ns
10us ~ ≒ 1 Frame ([Height]=3840:
42619us Max) = [Exposure Time Settings]
419 us
≒ 1 frame
(1) V-Binning Off
= ([Height]×659.31÷60MHz) + 132 us
(2) V-Binning On
= ([Height]×1318.61÷60MHz) + 132 us
- 93 -
Main Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-20000c-pmcl

Table of Contents