SP-20000-PMCL User Manual (Ver. 3.1)
Analog Control
Related Topic:
Gain
Name
GainRawAnalogAll
GainRawDigitalRedAll
GainRawDigitalBlueAll
GainAuto
BlackLevelRawAll
BlackLevelRaw
Tap1All
BlackLevelRaw
Tap1Red
BlackLevelRaw
Tap1Blue
BalanceWhiteAuto
Control,
Black Level
Short
Access
Values
ASCII
R/W
FGA
100 ~ 1600
R/W
PGR
- 4533 ~ 17713
R/W
PGB
- 4533 ~ 17713
0: Off
R/W
AGC
1: Continuous
2: Once
R/W
BL
- 256 ~ 255
R/W
BL1
- 512 ~ 511
R/W
BLR1 - 512 ~ 511
R/W
BLB1
- 512 ~ 511
0: Off
R/W
AWB
1: Continuous
2: Once
Control,
Balance White Auto
DEFAULT
FGA=[Param.]<CR><LF>
FGA?<CR><LF>
100
Set the gain value.
PGR=[Param.]<CR><LF>
PGR?<CR><LF>
0
Set the red gain value for white balance control.
PGB=[Param.]<CR><LF>
PGB?<CR><LF>
0
Set the blue gain value for white balance control.
AGC=[Param.]<CR><LF>
AGC?<CR><LF>
0
Enable/disable gain auto adjustment.
BL=[Param.]<CR><LF>
BL?<CR><LF>
0
Set the black level value.
BL1=[Param.]<CR><LF>
BL1?<CR><LF>
0
Set the black level Tap1 value.
BLR1=[Param.]<CR><LF>
BLR1?<CR><LF>
0
Set the red gain value for black balance control.
BLB1=[Param.]<CR><LF>
BLB1?<CR><LF>
0
Set the blue gain value for black balance control.
AWB=[Param.]<CR><LF>
AWB?<CR><LF>
0
Set the auto white balance mode.
- 123 -
Short ASCII Command List
Description