Name
Access
RequestExposure
AutoResult
TriggerOption
Related Topic:
Trigger Control
AlcReference
Related Topic:
ALC (Automatic
Level Control)
GainAutoMax
Related Topic:
Gain Auto
GainAutoMin
RequestGainAuto
Result
Short
Min ~ Max
ASCII
0 = Complete.
1 = Too Bright.
2 = Too dark.
3 = Timeout
R/O
ASRS
Error.
4 = Busy.
5 = Limit.
6 = Trig is not
set as Normal.
0 = Off
R/W
TRGOP
2 = PIV
R/W
AGCF
1 ~ 100[%]
R/W
AGCGA 200 ~ 1600
R/W
AGCGI
100 ~ 1500
0 = Complete.
1 = Too Bright.
2 = Too dark.
3 = Timeout
R/O
AGRS
Error.
4 = Busy.
5 = Limit.
6 = Trig is not
set as Normal.
Default
ASRS?<CR><LF>
0
Display the Exposure Auto result.
TRGOP=[Param.]<CR><LF>
TRGOP?<CR><LF>
0
Configure the Trigger option.
AGCF=[Param.]<CR><LF>
AGCF?<CR><LF>
50
Set the target level for ALC. (unit: %)
AGCGA=[Param.]<CR><LF>
AGCGA?<CR><LF>
1600
Set the maximum value for the Gain Auto (AGC) control
range.
AGCGI=[Param.]<CR><LF>
AGCGI?<CR><LF>
100
Set the minimum value for the Gain Auto (AGC) control
range.
AGRS?<CR><LF>
0