Tap Geometry: 1X2-1Y

Item
1Line Control Start Exposure
Time value [Unit: us]
1Line Control End Exposure
Time value [Unit: us]
When overlapped, Exposure
Time effective step value [Unit:
us/step]
Exposure Start Position [Unit:
Line]
Exposure Time Max value
Camera
Binning
Continuous trigger readout / exposure overlapped period Exposure
Link Pixel
Vertical
Clock
ROUND([Frame Rate (Time)] - ((([Height]×2618.54) + 49865 - 2618.54 +
80MHz
([Width]÷2)) ÷[Camera Link Clock Frequency:80MHz]×(10^6)))
1 (Off)
ROUND([Frame Rate (Time)] - ((([Height]×2637.25) + 50223 - 2637.25 +
60MHz
([Width]÷2)) ÷[Camera Link Clock Frequency:60MHz]×(10^6)))
ROUND([Frame Rate (Time)] - ((([Height]×5237.09) + 49865 - 2560 +
80MHz
([Width]÷2)) ÷[Camera Link Clock Frequency:80MHz]×(10^6)))
2 (On)
ROUND([Frame Rate (Time)] - ((([Height]×5274.49) + 50223 - 2560 +
60MHz
([Width]÷2)) ÷[Camera Link Clock Frequency:60MHz]×(10^6)))
ROUND([Frame Rate (Time)] - (49865÷[Camera Link Clock
80MHz
Frequency:80MHz]×(10^6))
1 (Off),
2 (On)
ROUND([Frame Rate (Time)] - (50223÷[Camera Link Clock
60MHz
Frequency:60MHz]×(10^6))
80MHz
ROUNDDOWN(2618.54÷[Camera Link Clock Frequency]×10^6)
1 (Off)
60MHz
ROUNDDOWN(2637.25÷[Camera Link Clock Frequency]×10^6)
80MHz
ROUNDDOWN(5237.09÷[Camera Link Clock Frequency])×10^6÷2)
2 (On)
60MHz
ROUNDDOWN(5274.49÷[Camera Link Clock Frequency])×10^6÷2)
[Height] - 1 - (ROUNDDOWN( ( [Exposure Time] - [1Line Control Start
80MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:80MHz]÷2618.54))
1 (Off)
[Height] - 1 - (ROUNDDOWN( ( [Exposure Time] - [1Line Control Start
60MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:80MHz]÷2637.25))
[Height] - 0.5 - (ROUNDDOWN( ( [Exposure Time] - [1Line Control Start
80MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:80MHz]÷5237.09)÷2)
2 (On)
[Height] - 0.5 - (ROUNDDOWN( ( [Exposure Time] - [1Line Control Start
60MHz
Exposure Time value] ) ×(10^-6)×[Camera Link Clock
Frequency:60MHz]÷5274.49)÷2)
ROUNDDOWN([Frame Rate (Time)] - (41200÷[Camera Link Clock
80MHz
Frequency:80MHz]×10^6))
1 (Off),
2 (On)
ROUNDDOWN([Frame Rate (Time)] - (41200÷[Camera Link Clock
60MHz
Frequency:60MHz]×10^6))
Time value calculation formula