IAI SP-20000M-PMCL User Manual page 90

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)
TapGeometry: 1X4-1Y
Camera Link
Binning
Clock
Vertical
1 (Off)
80MHz
2 (On)
1 (Off)
60MHz
2 (On)
Minimum Trigger Interval calculation formula [Unit: us]
At the condition of [Trigger Pulse Width] ≦ [Trigger Period: us] - 266us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) ×1309.27) - 1309.27 +
([Width]÷4))÷80MHz×10^6)+339
(2) If [Trigger Pulse Width] is more than 1Frame = 266 + [Trigger Pulse Width]
At the condition of [Trigger Pulse Width] ≦ [Trigger Period: us] - 266us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) ×2618.53) - 1280 +
([Width]÷4))÷80MHz×10^6)+339
(2) If [Trigger Pulse Width] is more than 1Frame = 266 + [Trigger Pulse Width]
= 266 + [Trigger Pulse Width] 60 MHz 1 (Off) At the condition of [Trigger Pulse Width] ≦ [Trigger
Period: us] - 353us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) ×1318.61) - 1318.61 +
([Width]÷4))÷60MHz×10^6)+452
(2) If [Trigger Pulse Width] is more than 1Frame = 353 + [Trigger Pulse Width]
At the condition of [Trigger Pulse Width] ≦ [Trigger Period: us] - 353us
(1) If [Trigger Pulse Width] is less than 1Frame = ROUND(((([Height] + 1) ×2637.23) - 1280 +
([Width]÷4))÷60MHz×10^6)+452
(2) If [Trigger Pulse Width] is more than 1Frame = 353 + [Trigger Pulse Width]
Trigger Width/ Trigger Overlap = Readout
- 90 -
Main Functions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-20000c-pmcl

Table of Contents