IAI SP-20000M-PMCL User Manual page 127

Cmos digital progressive scan monochrome and color camera with mini camera link interface
Table of Contents

Advertisement

SP-20000-PMCL User Manual (Ver. 3.1)
Sequencer Control
Related Topic:
Sequence ROI Setting Parameters
Name
Access
VideoSendMode
Related Topic:
Multi ROI
Function
SequenceRoiFrame
Count n
n = 1 ~ 10
SequenceRoi
NextIndex n
n = 1 ~ 10
SequenceRoi
Width n
n = 1 ~ 10
SequenceRoi
Heightn
n = 1 ~ 10
SequenceRoi
OffsetX n
n = 1 ~ 10
SequenceRoi
OffsetY n
n = 1 ~ 10
Short
Min ~ Max
ASCII
0: Normal
1: Trigger
Sequence
R/W
VSM
2: Command
Sequence
3: MultiROI
R/W
SQF n
1 ~ 255
0: Index1
1: Index2
2: Index3
3: Index4
4: Index5
R/W
SQNIn
5: Index6
6: Index7
7: Index8
8: Index9
9: Index10
8 ~ (5120 -
R/W
SQWn
OffsetX)
1 ~ (3840 -
R/W
SQHn
OffsetY)
0 ~ (5112
R/W
SQOXn
- Width)
0 ~ (3839 -
R/W
SQOYn
Height)
Default
VSM=[Param.]<CR><LF>
VSM?<CR><LF>
0
Configure Video Send Mode.
SQF n=[Param.]<CR><LF>
SQF n?<CR><LF>
1
Set the frame count of Sequence Roi Index n.
SQNI n=[Param.]<CR><LF>
SQNI n?<CR><LF>
0
Set the index to be executed after Sequence Roi Index n.
(Only enabled during Trigger Sequence Mode.)
SQW n=[Param.]<CR><LF>
SQW n?<CR><LF>
5120
Set the width of Sequence Roi Index n. See Width in
Format
Control.
SQH n=[Param.]<CR><LF>
SQH n?<CR><LF>
3840
Set the height of Sequence Roi Index n.
SQOX n=[Param.]<CR><LF>
SQOX n?<CR><LF>
0
Set the Offset X of Sequence Roi Index n.
SQOY n=[Param.]<CR><LF>
SQOY n?<CR><LF>
0
Set the Offset Y of Sequence Roi Index n.
- 127 -
Short ASCII Command List
Description
Image

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-20000c-pmcl

Table of Contents