SP-20000-PMCL User Manual (Ver. 3.1)

Gain Control

Related Setting Items:
This camera can adjust the gain level from x1 (0dB) to 16 times (+24dB) using x1 (0dB) as the
reference (Factory default). The master gain can be adjusted from x1 (0dB) to 16 times (+24dB) and R
and B gains can be adjusted in the range of 0.45 times (-7dB) to 7.15 times (+10dB) using the master
gain as the reference.
Resolution:
Master Gain: x0.01 (0.035dB)/Step
l
Blue/Red Gain: x0.00017 /Step
l
The master gain uses digital gain. All digital gain has the resolution of x0.01 /Step and provides more
precise gain setting. However, as it uses only digital gain, please note that if high gain is set, breaks in
the histogram may occur.
Model
Monochrome
Color
Analog Control
Gain Selector
Digital All
Digital All
Digital Red
Digital Blue
100 ~ 1600 (0dB ~ 24dB)
100 ~ 1600 (0dB ~ 24dB)
-4533 ~ +17713 (-7dB ~ +10dB)
-4533 ~ +17713 (-7dB ~ +10dB)