SP-20000-PMCL User Manual (Ver. 3.1)
Minimum Trigger Interval Calculation Formula (Trigger Overlap = Off, Trig-
gerWidth Mode)
Tap Geometry
Camera Link Pixel Clock
1X8-1Y
1X4-1Y
1X2-1Y
Note: When Trigger Overlap is set to OFF, if the trigger pulse is input in shorter period than the
period listed in the above trigger interval, this trigger input may be ignored by the trigger mask.
Binning Vertical
1 (Off)
80MHz
2 (On)
1 (Off)
60MHz
2 (On)
1 (Off)
80MHz
2 (On)
1 (Off)
60MHz
2 (On)
1 (Off)
80MHz
2 (On)
1 (Off)
60MHz
2 (On)
Trigger Width / Trigger Overlap = Off
Minimum Trigger interval calculation formula [Unit: us]
= ROUND(((([Height]+1) ×654.63) − 654.63 + ([Width]÷8) )
÷ 80MHz x 10^6) +321+ [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×1309.27) − 640 + ([Width]÷8) )
÷ 80MHz x 10^6) + 321 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×659.31) − 659.31 + ([Width]÷8) )
÷ 60MHz x 10^6) + 431 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×1318.61) − 640 + ([Width]÷8) )
÷ 60MHz x 10^6) + 431 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×1309.27) − 1309.27 + ([Width]÷4) )
÷ 80MHz x 10^6) + 329 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×2618.53) − 1280 + ([Width]÷4) )
÷ 80MHz x 10^6) + 329 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×1318.61) − 1318.61 + ([Width]÷4) )
÷ 60MHz x 10^6) + 442 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×2637.23) − 1280 + ([Width]÷4) )
÷ 60MHz x 10^6) + 442 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×2618.54) − 2618.54 + ([Width]÷2) )
÷ 80MHz x 10^6) + 657 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×5237.09) − 2560 + ([Width]÷2) )
÷ 80MHz x 10^6) + 657 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×2637.25) − 2637.25 + ([Width]÷2) )
÷ 60MHz x 10^6) + 882 + [Trigger Pulse Width:10us ~ ]
= ROUND(((([Height]+1) ×5274.49) − 2560 + ([Width]÷2) )
÷ 60MHz x 10^6) + 882 + [Trigger Pulse Width:10us ~ ]
- 88 -
Main Functions