14.3.9.
14.3.9. Replacing Eliminator Filter
Replacing Eliminator Filter
Capacitor (C2) – optional
Capacitor (C2) – optional
• See also Service Instruction (JD5078-02).
The optional eliminator filter (C2) consists of a single electrolytic capacitor with two (2) wires
connected directly to the Power Board (A2).
Preparation:
Preparation:
• Shut down and lock out all power to ATevo.
• Remove safety shield and check with a voltmeter.
• Locate the 'blue can' capacitor (C2), at the bottom-left of ATevo, secured to the
galvanized base with two (2) nylon zip ties.
Removal of Existing Capacitor:
Removal of Existing Capacitor:
• Cut the plastic ties and disconnect wires from the Power Board (A2).
• Remove the wired capacitor. Replacement capacitor (C2) is supplied with new wires and
pre-crimped terminals.
*
The pos(+) and neg(-) wires have different terminals to eliminate the possibility
of connecting in reverse polarity.
Installation of Replacement Capacitor Assembly:
Installation of Replacement Capacitor Assembly:
• Connect wires of new capacitor assembly (C2) to Power Board.
• Mount replacement cap to ATevo base with provided wire ties.
• Replace safety shield, and close front panel door.
• Restart ATevo.