Terminal Assignment; Device Plugs Available - Endress+Hauser Proline Promass E 500 PROFINET Operating Instructions Manual

Coriolis flowmeter
Table of Contents

Advertisement

Proline Promass E 500 PROFINET
Endress+Hauser
C: Connecting cable between sensor and transmitter: Proline 500
Standard cable
Conductor resistance
Capacitance: core/shield
Cable length (max.)
Cable lengths (available for
order)
Operating temperature
1)
UV radiation can impair the cable outer sheath. Protect the cable from direct sunshine where possible.
7.1.3

Terminal assignment

Transmitter: supply voltage, input/outputs
The terminal assignment of the inputs and outputs depends on the individual order
version of the device. The device-specific terminal assignment is documented on an
adhesive label in the terminal cover.
Supply voltage
Input/output
1
1 (+)
2 (–)
PROFINET
(RJ45 connector)
Transmitter and sensor connection housing: connecting cable
The sensor and transmitter, which are mounted in separate locations, are interconnected
by a connecting cable. The cable is connected via the sensor connection housing and the
transmitter housing.
Terminal assignment and connection of the connecting cable:
• Proline 500 – digital→  41
• Proline 500 →  51
7.1.4

Device plugs available

Device plugs may not be used in hazardous areas!
Order code for "Input; output 1", option RA "PROFINET"
Order code for
"Electrical connection"
L, N, P, U
1) 2)
1) 2)
1) 2)
1) 2)
R
, S
, T
, V
1)
Cannot be combined with an external WLAN antenna (order code for "Enclosed accessories", option P8) of
an RJ45 M12 adapter for the service interface (order code for "Accessories mounted", option NB) or of the
remote display and operating module DKX001.
2)
Suitable for integrating the device in a ring topology.
1)
2
6 × 0.38 mm
PVC cable
with common shield and individually shielded
cores
≤50 Ω/km (0.015 Ω/ft)
≤420 pF/m (128 pF/ft)
20 m (65 ft)
5 m (15 ft), 10 m (32 ft), 20 m (65 ft)
max. 105 °C (221 °F)
Input/output
2
24 (+)
25 (–)
Device-specific terminal assignment: adhesive label in terminal
Cable entry/connection
2
Connector M12 × 1
Connector M12 × 1
Electrical connection
Input/output
Input/output
3
22 (+)
23 (–)
20 (+)
cover.
3
Connector M12 × 1
4
21 (–)
39

Advertisement

Table of Contents
loading

Table of Contents