Endress+Hauser Proline Promass E 500 PROFINET Operating Instructions Manual page 237

Coriolis flowmeter
Table of Contents

Advertisement

Proline Promass E 500 PROFINET
Diagnostic information
No.
913 Medium unsuitable
Measured variable status [from the factory]
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
• Oscillation amplitude 1
• Oscillation amplitude 2
• Application specific output
• Application specific output
• Signal asymmetry
• Carrier mass flow
• Carrier pipe temperature
• Target corrected volume flow
• Carrier corrected volume flow
• Concentration
• Oscillation damping 1
• Oscillation damping 2
• Density
• Oil density
• Water density
• Dynamic viscosity
• Sensor electronic temperature (ISEM)
• GSV flow
1)
Diagnostic behavior can be changed. This causes the overall status of the measured variable to change.
Diagnostic information
No.
941 API temperature out of specification
Measured variable status [from the factory]
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
• Oil density
• Water density
• GSV flow
• GSV flow alternative
• Mass flow
• Oil mass flow
1)
Diagnostic behavior can be changed. This causes the overall status of the measured variable to change.
Endress+Hauser
Short text
1)
Good
Ok
0x80 to 0x83
S
Warning
• GSV flow alternative
• Kinematic viscosity
• Mass flow
• Oil mass flow
• Water mass flow
• Index inhomogeneous medium
• Index suspended bubbles
• HBSI
• NSV flow
• NSV flow alternative
• External pressure
• Exciter current 1
• Exciter current 2
• Oscillation frequency 1
• Oscillation frequency 2
• S&W volume flow
• Reference density
• Reference density alternative
Short text
1)
Bad
Maintenance alarm
0x24 to 0x27
S
Warning
• Water mass flow
• NSV flow
• NSV flow alternative
• External pressure
• S&W volume flow
• Reference density alternative
Remedy instructions
1. Check process conditions
2. Check electronic modules or sensor
• Corrected volume flow
• Oil corrected volume flow
• Water corrected volume flow
• Oscillation damping fluctuation 1
• Oscillation damping fluctuation 2
• Frequency fluctuation 1
• Frequency fluctuation 2
• Target mass flow
• Carrier volume flow
• Target volume flow
• Temp. compensated dynamic viscosity
• Temp. compensated kinematic viscosity
• Temperature
• Status
• Volume flow
• Oil volume flow
• Water volume flow
• Water cut
Remedy instructions
1. Check process temperature with selected API commodity group
2. Check API related parameters
• Corrected volume flow
• Oil corrected volume flow
• Water corrected volume flow
• Oil volume flow
• Water volume flow
• Water cut
Diagnostics and troubleshooting
237

Advertisement

Table of Contents
loading

Table of Contents