Endress+Hauser Proline Promass E 500 PROFINET Operating Instructions Manual page 157

Coriolis flowmeter
Table of Contents

Advertisement

Proline Promass E 500 PROFINET
Parameter
Frequency output simulation 1 to n
Frequency value 1 to n
Pulse output simulation 1 to n
Pulse value 1 to n
Switch output simulation 1 to n
Switch status 1 to n
Relay output 1 to n simulation
Switch status 1 to n
Pulse output simulation
Pulse value
Device alarm simulation
Diagnostic event category
Diagnostic event simulation
Logging interval
*
Visibility depends on order options or device settings
Endress+Hauser
Prerequisite
In the Operating mode
parameter, the Frequency
option is selected.
In the Frequency output
simulation 1 to n parameter,
the On option is selected.
In the Operating mode
parameter, the Pulse option is
selected.
In the Pulse output
simulation 1 to n parameter,
the Down-counting value
option is selected.
In the Operating mode
parameter, the Switch option
is selected.
The On option is selected in
the Switch output simulation
1 to n parameter parameter.
In the Pulse output
simulation parameter, the
Down-counting value option
is selected.
Description
Switch the simulation of the
frequency output on and off.
Enter the frequency value for
the simulation.
Set and switch off the pulse
output simulation.
For Fixed value option:
Pulse width parameter
(→  123) defines the
pulse width of the pulses
output.
Enter the number of pulses for
simulation.
Switch the simulation of the
switch output on and off.
Select the status of the status
output for the simulation.
Switch simulation of the relay
output on and off.
Select status of the relay
output for the simulation.
Set and switch off the pulse
output simulation.
For Fixed value option:
Pulse width parameter
defines the pulse width
of the pulses output.
Set and switch off the pulse
output simulation.
Switch the device alarm on and
off.
Select a diagnostic event
category.
Select a diagnostic event to
simulate this event.
Define the logging interval tlog
for data logging. This value
defines the time interval
between the individual data
points in the memory.
Commissioning
Selection / User
Factory setting
entry / User
interface
• Off
Off
• On
0.0 to 12 500.0 Hz
0.0 Hz
• Off
Off
• Fixed value
• Down-counting
value
0 to 65 535
0
• Off
Off
• On
• Open
Open
• Closed
• Off
Off
• On
• Open
Open
• Closed
• Off
Off
• Fixed value
• Down-counting
value
0 to 65 535
0
• Off
Off
• On
• Sensor
Process
• Electronics
• Configuration
• Process
• Off
Off
• Diagnostic event
picklist (depends
on the category
selected)
1.0 to 3 600.0 s
157