Proline Promass E 500 PROFINET
Parameter
Terminal number
Signal mode
0/4 mA value
20 mA value
Current span
Failure mode
Failure value
*
Visibility depends on order options or device settings
Endress+Hauser
Navigation
"Setup" menu → Current input
‣
Current input 1 to n
Terminal number
Signal mode
0/4 mA value
20 mA value
Current span
Failure mode
Failure value
Parameter overview with brief description
Prerequisite
–
The measuring device is not
approved for use in the
hazardous area with type of
protection Ex-i.
–
–
–
–
In the Failure mode
parameter, the Defined value
option is selected.
Description
Shows the terminal numbers
used by the current input
module.
Select the signal mode for the
current input.
Enter 4 mA value.
Enter 20 mA value.
Select current range for
process value output and
upper/lower level for alarm
signal.
Define input behavior in alarm
condition.
Enter value to be used by the
device if input value from
external device is missing.
Commissioning
→ 117
→ 117
→ 117
→ 117
→ 117
→ 117
→ 117
User interface /
Factory setting
Selection / User
entry
• Not used
–
• 24-25 (I/O 2)
• 22-23 (I/O 3)
• 20-21 (I/O 4)
• Passive
Active
*
• Active
Signed floating-point
0
number
Signed floating-point
Depends on country
number
and nominal
diameter
• 4...20 mA (4...
Country-specific:
20.5 mA)
• 4...20 mA NAMUR
• 4...20 mA NAMUR
(3.8...20.5 mA)
(3.8...20.5 mA)
• 4...20 mA US
• 4...20 mA US
(3.9...20.8 mA)
(3.9...20.8 mA)
• 0...20 mA (0...
20.5 mA)
• Alarm
Alarm
• Last valid value
• Defined value
Signed floating-point
0
number
117