Technical data
Low flow cut off
Galvanic isolation
Protocol-specific data
262
Light emitting diodes (LED)
Status information
The switch points for low flow cut off are user-selectable.
The outputs are galvanically isolated from one another and from earth (PE).
Protocol
Communication type
Conformity class
Netload Class
Baud rates
Cycle times
Polarity
Media Redundancy Protocol
(MRP)
System redundancy support
Device profile
Manufacturer ID
Device type ID
Device description files (GSD,
DTM, DD)
Supported connections
Configuration options for
measuring device
Configuration of the
device name
Status indicated by various light emitting diodes
The following information is displayed depending on the device version:
• Supply voltage active
• Data transmission active
• Device alarm/error has occurred
• PROFINET network available
• PROFINET connection established
• PROFINET blinking feature
Diagnostic information via light emitting diodes →  177
Application layer protocol for decentral device periphery and distributed
automation, Version 2.3
100 MBit/s
Conformance Class B
Netload Class II
Automatic 100 Mbit/s with full-duplex detection
From 8 ms
Auto-polarity for automatic correction of crossed TxD and RxD pairs
Yes
System redundancy S2 (2 AR with 1 NAP)
Application interface identifier 0xF600
Generic device
0x11
0x843B
Information and files under:
www.endress.com
On the product page for the device: Documents/Software → Device drivers
www.profibus.org
• 2 x AR (IO Controller AR)
• 1 x AR (IO-Supervisor Device AR connection allowed)
• 1 x Input CR (Communication Relation)
• 1 x Output CR (Communication Relation)
• 1 x Alarm CR (Communication Relation)
• DIP switches on the electronics module, for device name assignment (last
part)
• Manufacturer-specific software (FieldCare, DeviceCare)
• Web browser
• Device master file (GSD), can be read out via the integrated Web server of
the measuring device
• DIP switches on the electronics module, for device name assignment (last
part)
• DCP protocol
• Process Device Manager (PDM)
• Integrated Web server