Endress+Hauser Proline Promass E 500 PROFINET Operating Instructions Manual page 210

Coriolis flowmeter
Table of Contents

Advertisement

Diagnostics and troubleshooting
Diagnostic information
No.
375 I/O- 1 to n communication failed
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
• Oscillation amplitude 1
• Oscillation amplitude 2
• Application specific output
• Application specific output
• Signal asymmetry
• Carrier mass flow
• Carrier pipe temperature
• Target corrected volume flow
• Carrier corrected volume flow
• Concentration
• Measured values 1
• Measured values 2
• Measured values 3
• Oscillation damping 1
• Oscillation damping 2
• Density
• Oil density
• Water density
Diagnostic information
No.
378 Supply voltage ISEM faulty
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
210
Short text
Bad
Maintenance alarm
0x24 to 0x27
F
Alarm
• Dynamic viscosity
• Sensor electronic temperature (ISEM)
• GSV flow
• GSV flow alternative
• Kinematic viscosity
• Mass flow
• Oil mass flow
• Water mass flow
• Index inhomogeneous medium
• Index suspended bubbles
• HBSI
• NSV flow
• NSV flow alternative
• External pressure
• Exciter current 1
• Exciter current 2
• Oscillation frequency 1
• Oscillation frequency 2
Short text
Good
Ok
0x80 to 0x83
F
Alarm
Remedy instructions
1. Restart device
2. Check if failure recurs
3. Replace module rack inclusive electronic modules
• S&W volume flow
• Reference density
• Reference density alternative
• Corrected volume flow
• Oil corrected volume flow
• Water corrected volume flow
• Oscillation damping fluctuation 1
• Oscillation damping fluctuation 2
• Frequency fluctuation 1
• Frequency fluctuation 2
• Target mass flow
• Carrier volume flow
• Target volume flow
• Temp. compensated dynamic viscosity
• Temp. compensated kinematic viscosity
• Temperature
• Status
• Volume flow
Remedy instructions
Check supply voltage to the ISEM
Proline Promass E 500 PROFINET
Endress+Hauser

Advertisement

Table of Contents
loading

Table of Contents