Proline Promass E 500 PROFINET
Vibration- and shock-
resistance
Mechanical load
Electromagnetic
compatibility (EMC)
Medium temperature range
Endress+Hauser
External WLAN antenna
IP67
Vibration broad-band random, according to IEC 60068-2-6
Sensor
• 2 to 8.4 Hz, 3.5 mm peak
• 8.4 to 2 000 Hz, 1 g peak
Transmitter
• 2 to 8.4 Hz, 7.5 mm peak
• 8.4 to 2 000 Hz, 2 g peak
Vibration broad-band random, according to IEC 60068-2-64
Sensor
• 10 to 200 Hz, 0.003 g
2
• 200 to 2 000 Hz, 0.001 g
• Total: 1.54 g rms
Transmitter
• 10 to 200 Hz, 0.01 g
2
/Hz
• 200 to 2 000 Hz, 0.003 g
• Total: 2.70 g rms
Shock half-sine, according to IEC 60068-2-27
• Sensor
6 ms 30 g
• Transmitter
6 ms 50 g
Rough handling shocks, according to IEC 60068-2-31
Never use the transmitter housing as a ladder or climbing aid.
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Details are provided in the Declaration of Conformity.
16.9

Process

–40 to +150 °C (–40 to +302 °F)
/Hz
2
/Hz
2
/Hz
Technical data
269