Coriolis flowmeter
Hide thumbs Also See for Proline Promass E 200:
Table of Contents

Advertisement

BA01314D/06/EN/01.14
71258948
Valid as of version
01.00.zz (Device firmware)
Products

Operating Instructions

Proline Promass E 200
FOUNDATION Fieldbus
Coriolis flowmeter
Solutions
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Proline Promass E 200

  • Page 1: Operating Instructions

    Products Solutions Services BA01314D/06/EN/01.14 71258948 Valid as of version 01.00.zz (Device firmware) Operating Instructions Proline Promass E 200 FOUNDATION Fieldbus Coriolis flowmeter...
  • Page 2 • The manufacturer reserves the right to modify technical data without prior notice. Your Endress+Hauser Sales Center will supply you with current information and updates to these Instructions. Endress+Hauser...
  • Page 3: Table Of Contents

    Proline Promass E 200 FOUNDATION Fieldbus Table of contents Table of contents Post-installation check ....25 Document information ....6 Document function .
  • Page 4 13.3 Endress+Hauser services ....109 parameter ..... 78 10.7 Simulation .
  • Page 5 Proline Promass E 200 FOUNDATION Fieldbus Table of contents 16.6 Performance characteristics ... . . 123 16.7 Installation ......126 16.8 Environment .
  • Page 6: Document Information

    Document information Proline Promass E 200 FOUNDATION Fieldbus Document information Document function These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
  • Page 7: Tool Symbols

    Proline Promass E 200 FOUNDATION Fieldbus Document information 1.2.3 Tool symbols Symbol Meaning Flat blade screwdriver Allen key Open-ended wrench 1.2.4 Symbols for certain types of information Symbol Meaning Permitted Indicates procedures, processes or actions that are permitted. Preferred Indicates procedures, processes or actions that are preferred.
  • Page 8: Documentation

    • The W@M Device Viewer : Enter the serial number from the nameplate (www.endress.com/deviceviewer) • The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2-D matrix code (QR code) on the nameplate. For a detailed list of the individual documents along with the documentation code 1.3.1...
  • Page 9: Basic Safety Instructions

    ‣ Observe the specified pressure and temperature range. Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any Endress+Hauser...
  • Page 10: Workplace Safety

    It meets general safety standards and legal requirements. It also complies with the EC directives listed in the device-specific EC Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device.
  • Page 11: It Security

    Proline Promass E 200 FOUNDATION Fieldbus Basic safety instructions IT security We only provide a warranty if the device is installed and used as described in the Operating Instructions. The device is equipped with security mechanisms to protect it against any inadvertent changes to the device settings.
  • Page 12: Product Description

    Product description Proline Promass E 200 FOUNDATION Fieldbus Product description Product design A0014056  1 Important components of a measuring device Electronics compartment cover Display module Main electronics module Cable glands Transmitter housing (incl. integrated HistoROM) I/O electronics module Terminals (spring loaded terminals, pluggable) Connection compartment cover Sensor (incl.
  • Page 13: Incoming Acceptance And Product

    • If one of the conditions is not satisfied, contact your Endress+Hauser Sales Center. • Depending on the device version, the CD-ROM might not be part of the delivery! In such cases, the technical documentation is available via the Internet or via the Endress+Hauser Operations App, see the "Product identification"...
  • Page 14: Transmitter Nameplate

    "Supplementary device-dependent documentation" (→  8) • The W@M Device Viewer: Enter the serial number from the nameplate (www.endress.com/deviceviewer) • The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2-D matrix code (QR code) on the nameplate. 4.2.1...
  • Page 15: Sensor Nameplate

    Proline Promass E 200 FOUNDATION Fieldbus Incoming acceptance and product identification 4.2.2 Sensor nameplate 3 4 5 6 Order code: Ser. no.: Ext. ord. cd.: Size: Ptest = Material: 0044 Patents Date: 322541-0000 13 14 A0013907  3 Example of a sensor nameplate...
  • Page 16: Symbols On Measuring Device

    Incoming acceptance and product identification Proline Promass E 200 FOUNDATION Fieldbus 4.2.3 Symbols on measuring device Symbol Meaning WARNING!  This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury.
  • Page 17: Storage And Transport

    Proline Promass E 200 FOUNDATION Fieldbus Storage and transport Storage and transport Storage conditions Observe the following notes for storage: • Store in the original packaging to ensure protection from shock. • Do not remove protective covers or protective caps installed on process connections.
  • Page 18: Packaging Disposal

    Storage and transport Proline Promass E 200 FOUNDATION Fieldbus Packaging disposal All packaging materials are environmentally friendly and 100% recyclable: • Measuring device secondary packaging: polymer stretch film that conforms to EC Directive 2002/95/EC (RoHS). • Packaging: – Wood crate, treated in accordance with ISPM 15 standard, which is confirmed by the affixed IPPC logo.
  • Page 19: Installation

    Proline Promass E 200 FOUNDATION Fieldbus Installation Installation Installation conditions No special measures such as supports are necessary. External forces are absorbed by the construction of the device. 6.1.1 Mounting position Mounting location To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid the following mounting locations in the pipe: •...
  • Page 20 Installation Proline Promass E 200 FOUNDATION Fieldbus Ø orifice plate, pipe restriction [mm] [in] [mm] [in] ³⁄₈ 0.24 ½ 0.40 0.55 1½ 0.87 1.10 Orientation The direction of the arrow on the sensor nameplate helps you to install the sensor according to the flow direction (direction of medium flow through the piping).
  • Page 21: Requirements From Environment And Process

    Proline Promass E 200 FOUNDATION Fieldbus Installation Inlet and outlet runs No special precautions need to be taken for fittings which create turbulence, such as valves, elbows or T-pieces, as long as no cavitation occurs (→  21). A0015597 A0015598 Installation dimensions For the dimensions and installation lengths of the device, see the "Technical...
  • Page 22: Special Mounting Instructions

    Installation Proline Promass E 200 FOUNDATION Fieldbus NOTICE Electronics overheating on account of thermal insulation! ‣ Observe maximum permitted insulation height of the transmitter neck so that the transmitter head is completely free. mm (in) A0016749 Heating NOTICE Electronics can overheat due to elevated ambient temperature! ‣...
  • Page 23: Mounting The Measuring Device

    Proline Promass E 200 FOUNDATION Fieldbus Installation RUPTURE DISK A0007823  6 Rupture disk label ‣ After the rupture disk is actuated, do not operate the measuring device any more. WARNING Limited functional reliability of the rupture disk. Danger to persons from escaping fluids! ‣...
  • Page 24: Mounting The Measuring Device

    Installation Proline Promass E 200 FOUNDATION Fieldbus 6.2.3 Mounting the measuring device WARNING Danger due to improper process sealing! ‣ Ensure that the inside diameters of the gaskets are greater than or equal to that of the process connections and piping.
  • Page 25: Post-Installation Check

    Proline Promass E 200 FOUNDATION Fieldbus Installation 3 mm A0013905 1. Loosen the securing clamp of the electronics compartment cover using an Allen key. 2. Unscrew cover of the electronics compartment from the transmitter housing. 3. Optional: pull out the display module with a gentle rotational movement.
  • Page 26: Electrical Connection

    Electrical connection Proline Promass E 200 FOUNDATION Fieldbus Electrical connection The measuring device does not have an internal circuit breaker. For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
  • Page 27: Terminal Assignment

    Proline Promass E 200 FOUNDATION Fieldbus Electrical connection 7.1.3 Terminal assignment Transmitter Connection version for FOUNDATION Fieldbus, pulse/frequency/switch output A0013570 A0018161 Maximum number of terminals Maximum number of terminals for order code for "Accessory mounted", option NA "Overvoltage protection" Output 1: FOUNDATION Fieldbus...
  • Page 28: Requirements For The Supply Unit

    Electrical connection Proline Promass E 200 FOUNDATION Fieldbus A0019004 Controller (e.g. PLC) Power Conditioner (FOUNDATION Fieldbus) Cable shield T-box Measuring device Local grounding Bus terminator Potential matching line 7.1.5 Requirements for the supply unit Supply voltage Transmitter An external power supply is required for each output. The following supply voltage values...
  • Page 29: Connecting The Measuring Device

    Proline Promass E 200 FOUNDATION Fieldbus Electrical connection Connecting the measuring device NOTICE Limitation of electrical safety due to incorrect connection! ‣ Have electrical connection work carried out by correspondingly trained specialists only. ‣ Observe applicable federal/national installation codes and regulations.
  • Page 30: Special Connection Instructions

    Electrical connection Proline Promass E 200 FOUNDATION Fieldbus Removing a cable 3 (0.12) mm (in) A0013835 ‣ To remove a cable from the terminal, use a flat-blade screwdriver to push the slot between the two terminal holes while simultaneously pulling the cable end out of the terminal.
  • Page 31: Ensuring The Degree Of Protection

    Proline Promass E 200 FOUNDATION Fieldbus Electrical connection Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure. To guarantee IP66/67 degree of protection, Type 4X enclosure, carry out the following steps after the electrical connection: 1.
  • Page 32: Operation Options

    Operation options Proline Promass E 200 FOUNDATION Fieldbus Operation options Overview of operation options A0015607 Local operation via display module Computer with operating tool (e.g. FieldCare, AMS Device Manager) Field Xpert SFX350 or SFX370 Field Communicator 475 Control system (e.g. PLC)
  • Page 33: Structure And Function Of The Operating Menu

    Proline Promass E 200 FOUNDATION Fieldbus Operation options Structure and function of the operating menu 8.2.1 Structure of the operating menu For an overview of the operating menu with menus and parameters (→  138) Operating menu for operators and maintenances...
  • Page 34: Operating Philosophy

    Operation options Proline Promass E 200 FOUNDATION Fieldbus 8.2.2 Operating philosophy The individual parts of the operating menu are assigned to certain user roles. Each user role corresponds to typical tasks within the device lifecycle. Access to the operating menu via the local display 8.3.1...
  • Page 35: Navigation View

    Proline Promass E 200 FOUNDATION Fieldbus Operation options • Density • Reference density Temperature Totalizer  The measurement channel number indicates which of the three totalizers is displayed. Measurement channel numbers Symbol Meaning Measurement channel 1 to 4 The measurement channel number is displayed only if more than one channel is present for the same measured variable type (e.g.
  • Page 36 Operation options Proline Promass E 200 FOUNDATION Fieldbus / ../ Display For more information about the menu icons, refer to the "Display area" section (→  36) Status area The following appears in the status area of the navigation view in the top right corner: •...
  • Page 37: Editing View

    Proline Promass E 200 FOUNDATION Fieldbus Operation options Wizard operation Symbol Meaning Switches to the previous parameter. Confirms the parameter value and switches to the next parameter. Opens the editing view of the parameter. 8.3.3 Editing view Numeric editor Text editor...
  • Page 38 Operation options Proline Promass E 200 FOUNDATION Fieldbus Text editor Symbol Meaning Toggle • Between upper-case and lower-case letters • For entering numbers • For entering special characters Selection of letters from A to Z. ABC _ … Selection of letters from a to z.
  • Page 39: Operating Elements

    Proline Promass E 200 FOUNDATION Fieldbus Operation options 8.3.4 Operating elements Meaning Minus key In a menu, submenu Moves the selection bar upwards in a choose list. With a Wizard Confirms the parameter value and goes to the previous parameter.
  • Page 40 Operation options Proline Promass E 200 FOUNDATION Fieldbus • Setup • Conf. backup disp. • Simulation Calling up and closing the context menu The user is in the operational display. 1. Press  for 2 s.  The context menu opens.
  • Page 41: Navigating And Selecting From List

    Proline Promass E 200 FOUNDATION Fieldbus Operation options 8.3.6 Navigating and selecting from list Different operating elements are used to navigate through the operating menu. The navigation path is displayed on the left in the header. Icons are displayed in front of the individual menus.
  • Page 42: Calling Up Help Text

    Operation options Proline Promass E 200 FOUNDATION Fieldbus Navigation path "Expert" menu → Direct access The direct access code consists of a 4-digit number and the channel number, which identifies the channel of a process variable: e.g. 0914-1. In the navigation view, this appears on the right-hand side in the header of the selected parameter.
  • Page 43: Changing The Parameters

    Proline Promass E 200 FOUNDATION Fieldbus Operation options 8.3.9 Changing the parameters For a description of the editing display - consisting of text editor and numeric editor - with symbols (→  37), for a description of the operating elements (→  39) Example: Changing the tag name in the "Tag description"...
  • Page 44: User Roles And Related Access Authorization

    Operation options Proline Promass E 200 FOUNDATION Fieldbus 8.3.10 User roles and related access authorization The two user roles "Operator" and "Maintenance" have different write access to the parameters if the customer defines a user-specific access code. This protects the device configuration via the local display from unauthorized access (→...
  • Page 45: Access To The Operating Menu Via The Operating Tool

    Proline Promass E 200 FOUNDATION Fieldbus Operation options Switching off the keypad lock ‣ The keypad lock is switched on. Press the  +  +  keys simultaneously.  The message Keylock off appears on the display: The keypad lock is switched off.
  • Page 46: Connecting The Operating Tool

    FOUNDATION Fieldbus FF-H1 network Power supply FF-H1 network T-box Measuring device Via service interface (CDI) A0014019 Service interface (CDI = Endress+Hauser Common Data Interface) of the measuring device Commubox FXA291 Computer with "FieldCare" operating tool with COM DTM "CDI Communication FXA291" Endress+Hauser...
  • Page 47: Field Xpert Sfx350, Sfx370

    FieldCare Function scope FDT-based plant asset management tool from Endress+Hauser. It can configure all smart field devices in a system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition.
  • Page 48: Ams Device Manager

    Operation options Proline Promass E 200 FOUNDATION Fieldbus User interface Xxxxxx/…/…/ Device name: Xxxxxxx Mass flow: kg/h 12.34 Device tag: Xxxxxxx Volume flow: 12.34 m /h ³ Status: Good Xxxxxx Mass flow unit: kg/h Access status tooling Maintenance Volume flow unit: m /h ³...
  • Page 49: System Integration

    Proline Promass E 200 FOUNDATION Fieldbus System integration System integration Overview of device description files 9.1.1 Current version data for the device Manufacturer ID 452B48 hex Manufacturer ID parameter Diagnostics → Device info→ Manufacturer ID Device type ID 0x1054 Device type parameter Diagnostics →...
  • Page 50: Integration Into A Foundation Fieldbus Network

    System integration Proline Promass E 200 FOUNDATION Fieldbus Integration into a FOUNDATION Fieldbus network 9.2.1 Block model • Resource Block • Transducer Blocks – Setup Transducer Block – Advanced Setup Transducer Block – Display Transducer Block – HistoROM Transducer Block –...
  • Page 51: Index Tables Of Endress+Hauser Parameters

    Proline Promass E 200 FOUNDATION Fieldbus System integration Channel Signal Empty pipe detection Status verification Multiple Analog Output Block (MAO) Structure Channel_0 Value 1 Value 2 Value 3 Value 4 Value 5 Value 6 Value 7 Value 8 Channel Measured variable...
  • Page 52: Methods

    System integration Proline Promass E 200 FOUNDATION Fieldbus 9.2.4 Methods Method Block / accessibility via menu Description Set to "AUTO" Block: – This method sets the Resource Block and all the mode Accessibility via menu: Configure/Setup → Transducer Blocks to the AUTO (Automatic) Expert →...
  • Page 53 Proline Promass E 200 FOUNDATION Fieldbus System integration Method Block / accessibility via menu Description Diagnostics 3 – Block: Diagnostic Transducer Block This method is used to display remedial Remedy Accessibility via menu: Configure/Setup → measures for an additional active diagnostic information Diagnostics →...
  • Page 54: Commissioning

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus Commissioning 10.1 Function check Before commissioning the device, make sure that the post-installation and post- connection checks have been performed. • "Post-installation check" checklist (→  25) • "Post-connection check" checklist (→  31) 10.2...
  • Page 55: Defining The Tag Name

    Proline Promass E 200 FOUNDATION Fieldbus Commissioning X X X X X X X 20.50 0104-1 Main menu Language English Operation Setup Main menu Operation Setup Diagnostic / ../Setup Medium selection XXXXXXXXX XXXXXXXXX A0014007-EN  11 Using the example of the local display...
  • Page 56: Setting The System Units

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus XXXXXXXXX A0013375  12 Header of the operational display with tag name Device tag Navigation "Setup" menu → Device tag Parameter overview with brief description Parameter Description User entry Factory setting Device tag Enter the name for the measuring point.
  • Page 57 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Parameter overview with brief description Parameter Description Selection Factory setting Mass flow unit Select mass flow unit. Unit choose list Country-specific: • kg/h Result • lb/min The selected unit applies for: • Output •...
  • Page 58: Selecting And Setting The Medium

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus 10.4.3 Selecting and setting the medium The Medium selection wizard guides you systematically through all the parameters that have to be configured for selecting and setting the medium. Navigation "Setup" menu → Select medium...
  • Page 59 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Parameter Description Selection / User entry Factory setting Pressure compensation Select pressure compensation type. • Off • Fixed value • External value Pressure value Enter process pressure to be used for Positive floating-point number 101 325 bar pressure correction.
  • Page 60: Configuring The Analog Inputs

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus 10.4.4 Configuring the analog inputs The Analog inputs submenu guides you systematically to the individual Analog input 1 to 6 submenu. From here you get to the parameters of the individual analog input.
  • Page 61 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Structure of the wizard Format display Value 1 display 0% bargraph value 1 100% bargraph value 1 Value 2 display Value 3 display 0% bargraph value 3 100% bargraph value 3 Value 4 display...
  • Page 62 Commissioning Proline Promass E 200 FOUNDATION Fieldbus Parameter Description Selection / User entry Factory setting Value 2 display Select the measured value that is shown on Picklist (see 1st display value) None the local display. Value 3 display Select the measured value that is shown on...
  • Page 63: Configuring The Low Flow Cut Off

    Proline Promass E 200 FOUNDATION Fieldbus Commissioning 10.4.6 Configuring the low flow cut off The Low flow cut off wizard guides you systematically through all the parameters that have to be set for configuring the low flow cut off. Navigation "Setup"...
  • Page 64: Configuring The Partial Filled Pipe

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus 10.4.7 Configuring the partial filled pipe detection The Partial filled pipe detection wizard guides you systematically through all parameters that have to be set for configuring the monitoring of the pipe filling. Navigation "Setup"...
  • Page 65: Advanced Settings

    Proline Promass E 200 FOUNDATION Fieldbus Commissioning 10.5 Advanced settings The Advanced setup submenu with its submenus contains parameters for specific settings. Navigation to the "Advanced setup" submenu X X X X X X X 20.50 0104-1 Main menu Language...
  • Page 66: Carrying Out A Sensor Adjustment

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus ‣ Configuration backup display (→  77) ‣ Administration 10.5.1 Carrying out a sensor adjustment The Sensor adjustment submenu contains parameters that pertain to the functionality of the sensor. Navigation "Setup" menu → Advanced setup → Sensor adjustment...
  • Page 67 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Structure of the wizard for the pulse output Operating mode Pulse Assign pulse Volume flow Correct.vol.flow Mass flow Mass unit Volume unit Corr. vol. unit Corr. vol.flow. Calc ref density Fix ref.density Linear exp coeff Ref.
  • Page 68 Commissioning Proline Promass E 200 FOUNDATION Fieldbus Parameter Prerequsite Description Selection / User Factory setting entry Mass unit – Select mass unit. Unit choose list Country-specific: • kg Result • lb The selected unit is taken from: Mass flow unit parameter Volume unit –...
  • Page 69 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Configuring the frequency output Navigation "Setup" menu → Advanced setup → Pulse/frequency/switch output Structure of the wizard for the frequency output Operating mode Frequency Assign freq. Volume flow Density Temperature Ref.density Mass flow Correct.vol.flow...
  • Page 70 Commissioning Proline Promass E 200 FOUNDATION Fieldbus Parameter overview with brief description Parameter Description Selection / User entry Factory setting Operating mode Define the output as a pulse, frequency or • Pulse Pulse switch output. • Frequency • Switch Assign frequency output Select process variable for frequency output.
  • Page 71 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Parameter Description Selection / User entry Factory setting Failure mode Define output behavior in alarm condition. • Actual value 0 Hz • Defined value • 0 Hz Failure frequency Enter frequency output value in alarm 0.0 to 1 250.0 Hz...
  • Page 72 Commissioning Proline Promass E 200 FOUNDATION Fieldbus Operating mode Switch Switch out funct Fl. direct. Limit Status check Assign Assign Assign limit dir.check status Ref. Partial Mass Correct. Totalizer Mass Volume Correct. Low flow density pipe det. flow vol.flow 1/2/3...
  • Page 73 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Parameter Description Selection / User entry Factory setting Assign limit Select process variable for limit function. • Mass flow Mass flow • Volume flow • Corrected volume flow • Density • Reference density • Temperature •...
  • Page 74: Configuring The Totalizer

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus Parameter Description Selection / User entry Factory setting Failure mode Define output behavior in alarm condition. • Actual status Open • Open • Closed Invert output signal Invert the output signal. • No • Yes 10.5.3...
  • Page 75: Carrying Out Additional Display Configurations

    Proline Promass E 200 FOUNDATION Fieldbus Commissioning 10.5.4 Carrying out additional display configurations In the "Display" submenu you can set all the parameters involved in the configuration of the local display. Navigation "Setup" menu → Advanced setup → Display Display...
  • Page 76 Commissioning Proline Promass E 200 FOUNDATION Fieldbus Parameter overview with brief description Parameter Description Selection / User entry Factory setting Format display Select how measured values are shown on • 1 value, max. size 1 value, max. size the display. • 1 bargraph + 1 value •...
  • Page 77: Configuration Management

    Proline Promass E 200 FOUNDATION Fieldbus Commissioning Parameter Description Selection / User entry Factory setting Language Set display language. • English English (alternatively, the • Deutsch ordered language is preset in • Français the device) • Español • Italiano • Nederlands • Portuguesa •...
  • Page 78: Function Scope Of The ""Configuration Management" Parameter" Parameter

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus Parameter overview with brief description Parameter Description User interface / Selection Factory setting Operating time Indicates how long the device has been in Days (d), hours (h), minutes – operation. (m), seconds (s) Last backup...
  • Page 79 Proline Promass E 200 FOUNDATION Fieldbus Commissioning Simulation Assign simulation process variable Value process variable Frequency simulation Frequency value Pulse simulation Pulse value Switch output simulation Switch status Simulation device alarm Simulation diagnostic event Diagnostic event category Simulation diagnostic event...
  • Page 80: Protecting Settings From Unauthorized

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus Parameter Prerequsite Description Selection / User Factory setting entry Pulse value The Down-count. val. option Enter the number of pulses for 0 to 65 535 is selected in the Simulation simulation. pulse output parameter. Switch output simulation –...
  • Page 81: Write Protection Via Write Protection

    Proline Promass E 200 FOUNDATION Fieldbus Commissioning Defining the access code via local display 1. Navigate to the Enter access code parameter. 2. Define a max. 4-digit numeric code as an access code. 3. Enter the access code again to confirm the code.
  • Page 82: Write Protection Via Block Operation

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus A0013909 4. Setting the write protection switch (WP) on the main electronics module to the ON position enables the hardware write protection. Setting the write protection switch (WP) on the main electronics module to the OFF position (factory setting) disables the hardware write protection.
  • Page 83: Configuring The Measuring Device Via Foundation Fieldbus

    Proline Promass E 200 FOUNDATION Fieldbus Commissioning 10.9 Configuring the measuring device via FOUNDATION Fieldbus 10.9.1 Block configuration Preparation The correct Cff and device description files are needed for preparatory purposes. 1. Switch on the device. 2. Make a note of the DEVICE_ID.
  • Page 84: Scaling The Measured Value In The Analog Input Block

    Commissioning Proline Promass E 200 FOUNDATION Fieldbus 5. Via the Transducer scale/XD_SCALE parameter, select the desired unit and the block input range for the process variable. The selected unit must suit the selected process variable. If the process variable does not suit the unit, the Block error/ BLOCK_ERR parameter reports Block Configuration Error and the block mode cannot be set to Auto.
  • Page 85 Proline Promass E 200 FOUNDATION Fieldbus Commissioning • If you have selected the Direct mode in the L_TYPE parameter, you cannot change the values and units for XD_SCALE and OUT_SCALE. • The L_TYPE, XD_SCALE and OUT_SCALE parameters can only be changed in the OOS block mode.
  • Page 86: Operation

    Operation Proline Promass E 200 FOUNDATION Fieldbus Operation 11.1 Reading device locking status The write protection types that are currently active can be determined using the Locking status parameter. Navigation "Operation" menu → Locking status Function scope of "Locking status" parameter...
  • Page 87: Totalizer

    Proline Promass E 200 FOUNDATION Fieldbus Operation Corrected volume flow Density Reference density Temperature Parameter overview with brief description Parameter Description User interface Mass flow Displays the mass flow currently measured. Signed floating-point number Volume flow Displays the volume flow currently measured.
  • Page 88: Output Values

    Operation Proline Promass E 200 FOUNDATION Fieldbus 11.4.3 Output values The "Output values" submenu contains all the parameters needed to display the current measured values for every output. Navigation "Diagnostics" menu → Measured values → Output values Output values Terminal voltage 1...
  • Page 89: Showing Data Logging

    Proline Promass E 200 FOUNDATION Fieldbus Operation Options Description Reset + totalize The totalizer is reset to 0 and the totaling process is restarted. Preset + totalize The totalizer is set to the defined start value in Preset value parameterand the totaling process is restarted.
  • Page 90 Operation Proline Promass E 200 FOUNDATION Fieldbus A0016357  23 Chart of a measured value trend • x-axis: depending on the number of channels selected displays 250 to 1000 measured values of a process variable. • y-axis: displays the approximate measured value span and constantly adapts this to the ongoing measurement.
  • Page 91 Proline Promass E 200 FOUNDATION Fieldbus Operation Parameter overview with brief description Parameter Description Selection / User entry Factory setting Assign channel 1 to 4 Assign process variable to logging channel. • Off • Mass flow • Volume flow • Corrected volume flow •...
  • Page 92: Diagnostics And Troubleshooting

    Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting 12.1 General troubleshooting For local display Problem Possible causes Remedy Local display dark and no output Supply voltage does not match that Apply the correct supply voltage .
  • Page 93 Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting For access Problem Possible causes Remedy No write access to parameters Hardware write protection enabled Set the write protection switch on the main electronics module to the OFF position (→  81).
  • Page 94: Diagnostic Information On Local Display

    Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus 12.2 Diagnostic information on local display 12.2.1 Diagnostic message Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display.
  • Page 95: Calling Up Remedial Measures

    Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting Diagnostic behavior Symbol Meaning Alarm • Measurement is interrupted. • Signal outputs and totalizers assume the defined alarm condition. • A diagnostic message is generated. A0013961 • For local display with touch control: the background lighting changes to red.
  • Page 96: Diagnostic Information In Fieldcare

    Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus The user is in the diagnostic message. 1. Press  ( symbol).  The Diagnostic list submenu opens. 2. Select the desired diagnostic event with  or  and press  .
  • Page 97: Calling Up Remedy Information

    Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting Diagnostic information The fault can be identified using the diagnostic information. The short text helps you by providing information about the fault. In addition, the corresponding symbol for the diagnostic behavior is displayed in front of the diagnostic information on the local display.
  • Page 98 Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus Enabling the configuration of the diagnostic information according to FF912 For compatibility reasons, the configuration of the diagnostic information according to FOUNDATION Fieldbus Specification FF912 is not enabled when the device is delivered from the factory.
  • Page 99 Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting Weighting Status signal Allocation Diagnostic information range (factory setting) Low weighting Maintenance required (M) Sensor M000 to 199 Electronics M200 to 399 Configuration M400 to 700 Process M800 to 999 Changing the assignment of the diagnostic information The individual ranges of the diagnostic information can be assigned to another status signal.
  • Page 100 Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus 1. Set the Resource Block to the OOS block mode. 2. Open the FD_FAIL_MAP parameter in the Resource Block. 3. Change Bit 30 to 0 in the parameter. 4. Open the FD_CHECK_MAP parameter in the Resource Block.
  • Page 101: Overview Of Diagnostic Information

    Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting Transmitting the diagnostic information over the bus Prioritizing diagnostic information for transmission over the bus Diagnostic information is only transmitted over the bus if its priority is between 2 and 15.
  • Page 102 Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Module connection 1. Check module connections Alarm 2. Change electronic modules Main electronic failure Change main electronic module...
  • Page 103: Pending Diagnostic Events

    Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Switch output simulation Deactivate simulation switch output C Warning Simulation diagnostic Deactivate simulation Warning event...
  • Page 104: Diagnostic Messages In The Diagnostic Transducer Block

    Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus Structure of the submenu Diagnostics → Actual diagnostics Previous diagnostics Operating time from restart Operating time Parameter overview with brief description Parameter Prerequsite Description User interface Factory setting Actual diagnostics 1 diagnostic event has...
  • Page 105: Event Logbook

    Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting / ../Diagnose list Diagnostics F273 Main electronic Diagnostics 2 Diagnostics 3 A0014006-EN  25 Illustrated using the example of the local display To call up the measures to rectify a diagnostic event: •...
  • Page 106: 12.10 Resetting The Measuring Device

    Diagnostics and troubleshooting Proline Promass E 200 FOUNDATION Fieldbus Info number Info name I1089 Power on I1090 Configuration reset I1091 Configuration changed I1092 Trend data deleted I1110 Write protection switch changed I1111 Density adjust failure I1137 Electronic changed I1151 History reset...
  • Page 107: 12.11 Device Information

    Proline Promass E 200 FOUNDATION Fieldbus Diagnostics and troubleshooting "Setup" menu → Advanced setup → Administration Function scope of "Device reset" parameter Options Description Cancel No action is executed and the user exits the parameter. To delivery settings Every parameter for which a customer-specific default setting was ordered is reset to this customer-specific value.
  • Page 108: 12.12 Firmware History

    "Manufacturer' s information" document. The manufacturer' s information is available: • In the Download Area of the Endress+Hauser Internet site: www.endress.com → Download • Specify the following details: –...
  • Page 109: Maintenance

    (→  127). 13.2 Measuring and test equipment Endress+Hauser offers a wide variety of measuring and test equipment, such as W@M or device tests. Your Endress+Hauser Sales Center can provide detailed information on the services. For a list of some of the measuring and test equipment, refer to the "Accessories"...
  • Page 110: Repair

    • Spare parts are grouped into logical kits with the associated Installation Instructions. • Repairs are carried out by Endress+Hauser Service or by correspondingly trained customers. • Certified devices can be converted into other certified devices by Endress+Hauser Service or at the factory only. Notes for repair and conversion For repair and modification of a measuring device, observe the following notes: •...
  • Page 111: Endress+Hauser Services

    • Can be read out via the Serial number parameter in the Device information submenu (→  107). 14.3 Endress+Hauser services Contact your Endress+Hauser Sales Center for information on services and spare parts. 14.4 Return The measuring device must be returned if repairs or a factory calibration are required, or if the wrong measuring device has been ordered or delivered.
  • Page 112: Accessories

    Various accessories, which can be ordered with the device or subsequently from Endress +Hauser, are available for the device. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 113: For The Sensor

    Is used to stabilize the temperature of the fluids in the sensor. Water, water vapor and other non-corrosive liquids are permitted for use as fluids. If using oil as a heating medium, please consult with Endress+Hauser. Heating jackets cannot be used with sensors fitted with a rupture disk.
  • Page 114: System Components

    Accessories Proline Promass E 200 FOUNDATION Fieldbus 15.4 System components Accessories Description Memograph M graphic The Memograph M graphic display recorder provides information on all relevant display recorder measured variables. Measured values are recorded correctly, limit values are monitored and measuring points analyzed. The data are stored in the 256 MB internal memory and also on a SD card or USB stick.
  • Page 115: Technical Data

    Proline Promass E 200 FOUNDATION Fieldbus Technical data Technical data 16.1 Application The measuring device is suitable for flow measurement of liquids and gases only. Depending on the version ordered, the measuring device can also measure potentially explosive, flammable, poisonous and oxidizing media.
  • Page 116 To increase the accuracy of certain measured variables or to calculate the corrected volume flow for gases, the automation system can continuously write the operating pressure to the measuring device. Endress+Hauser recommends the use of a pressure transmitter for absolute pressure, e.g. Cerabar M or Cerabar S.
  • Page 117: Output

    Proline Promass E 200 FOUNDATION Fieldbus Technical data 16.4 Output Output signal Pulse/frequency/switch output Function Can be set to pulse, frequency or switch output Version Passive, open collector Maximum input values • DC 35 V • 50 mA Voltage drop •...
  • Page 118 Technical data Proline Promass E 200 FOUNDATION Fieldbus Signal on alarm Depending on the interface, failure information is displayed as follows: Pulse/frequency/switch output Pulse output Failure mode Choose from: • Actual value • No pulses Frequency output Failure mode Choose from: •...
  • Page 119 Proline Promass E 200 FOUNDATION Fieldbus Technical data DD revision Information and files under: • www.endress.com CFF revision • www.fieldbus.org Device Tester Version (ITK 6.1.1 version) ITK Test Campaign Number IT094200 Link Master capability (LAS) Choice of "Link Master" and "Basic Device"...
  • Page 120 Technical data Proline Promass E 200 FOUNDATION Fieldbus Block Contents Output values Expert Configuration Parameters that require the user to have in- No output values Transducer Block depth knowledge of the operation of the device (TRDEXP) in order to configure the parameters appropriately.
  • Page 121: Power Supply

    Proline Promass E 200 FOUNDATION Fieldbus Technical data Block Number Contents Process variables (Channel) Blocks PID Block This Block (standard functionality) acts as a – (PID) proportional-integral-differential controller and can be used universally for control in the field. It enables cascading and feedforward control.
  • Page 122 Technical data Proline Promass E 200 FOUNDATION Fieldbus Power consumption Transmitter Order code for "Output" Maximum power consumption Option E: FOUNDATION Fieldbus, pulse/ • Operation with output 1: 512 mW frequency/switch output • Operation with output 1 and 2: 2 512 mW...
  • Page 123: Performance Characteristics

    Proline Promass E 200 FOUNDATION Fieldbus Technical data Depending on the temperature class, restrictions apply to the ambient temperature for device versions with overvoltage protection . For detailed information on the temperature tables, see the separate document entitled "Safety Instructions" (XA) for the device.
  • Page 124 Technical data Proline Promass E 200 FOUNDATION Fieldbus SI units 1:10 1:20 1:50 1:100 1:500 [mm] [kg/h] [kg/h] [kg/h] [kg/h] [kg/h] [kg/h] 2 000 6 500 18 000 1 800 45 000 4 500 2 250 70 000 7 000...
  • Page 125 Proline Promass E 200 FOUNDATION Fieldbus Technical data Density When there is a difference between the density calibration temperature and the process temperature, the typical measured error of the sensor is ±0.0001 g/cm /°C (±0.00005 g/cm /°F). Field density calibration is possible.
  • Page 126: Installation

    Technical data Proline Promass E 200 FOUNDATION Fieldbus Calculation of the maximum repeatability as a function of the flow rate Flow rate Maximum repeatability in % o.r. ⋅ ⁄ ZeroPoint ⋅ ⋅ ± ½ BaseAccu ³ BaseAccu A0021343 A0021341 ⋅...
  • Page 127: Process

    Proline Promass E 200 FOUNDATION Fieldbus Technical data Sensor IP66/67, type 4X enclosure Shock resistance As per IEC/EN 60068-2-31 Vibration resistance Acceleration up to 1 g, 10 to 150 Hz, based on IEC/EN 60068-2-6 Interior cleaning • Sterilization in place (SIP) •...
  • Page 128 Technical data Proline Promass E 200 FOUNDATION Fieldbus • The minimum recommended full scale value is approx. 1/20 of the maximum full scale value • In most applications, 20 to 50 % of the maximum full scale value can be considered ideal •...
  • Page 129: 16.10 Mechanical Construction

    Proline Promass E 200 FOUNDATION Fieldbus Technical data 16.10 Mechanical construction Design, dimensions For the dimensions and installation lengths of the device, see the "Technical Information" document, "Mechanical construction" section Weight Compact version Weight in SI units All values (weight) refer to devices with EN/DIN PN 40 flanges. Weight information in [kg].
  • Page 130 Technical data Proline Promass E 200 FOUNDATION Fieldbus Cable entries/cable glands A0020640  30 Possible cable entries/cable glands Cable entry in transmitter housing, wall-mount housing or connection housing with internal thread M20 x Cable gland M20 x 1.5 Adapter for cable entry with internal thread G ½" or NPT ½"...
  • Page 131 Proline Promass E 200 FOUNDATION Fieldbus Technical data Surface quality: • Not polished • Ra = 0.8 µm (32 µin) • Ra = 0.4 µm (16 µin) Process connections • Flanges according to EN 1092-1 (DIN2501) / according to ASME B 16.5 / as per JIS B2220: Stainless steel, 1.4404 (F316/F316L)
  • Page 132: 16.11 Operability

    Technical data Proline Promass E 200 FOUNDATION Fieldbus 16.11 Operability Local operation Via display module Order code for "Display; Operation", option C "SD02" Order code for "Display; Operation", option E "SD03" A0015546 A0015544 Operation with pushbuttons Operation with touch control Display elements •...
  • Page 133 Proline Promass E 200 FOUNDATION Fieldbus Technical data Via remote display and operating module FHX50 A0013137  31 Operating options via FHX50 Housing of remote display and operating module FHX50 SD02 display and operating module, push buttons: cover must be opened for operation...
  • Page 134: 16.12 Certificates And Approvals

    EC Directives. These are listed in the corresponding EC Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media Authority (ACMA)".
  • Page 135 • The device can also be operated with certified devices of other manufacturers (interoperability) Pressure Equipment • With the PED/G1/x (x = category) marking on the sensor nameplate, Endress+Hauser Directive confirms compliance with the "Essential Safety Requirements" specified in Annex I of the Pressure Equipment Directive 97/23/EC.
  • Page 136: 16.13 Application Packages

    The application packages can be ordered from Endress+Hauser either directly with the device or subsequently. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 137 Proline Promass E 200 FOUNDATION Fieldbus Technical data Contents Documentation code NEPSI Ex d XA00155D NEPSI Ex nA XA00157D Special Documentation Contents Documentation code Information on the Pressure Equipment Directive SD00142D Heartbeat Technology SD01300D Installation Instructions Contents Documentation code ...
  • Page 138: Appendix

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Appendix The manufacturer-specific device parameters are listed in the index tables. FOUNDATION Fieldbus parameters: "Guideline - FOUNDATION Fieldbus Function Blocks" document (BA062S), available www.endress.com 17.1 Endress+Hauser FOUNDATION Fieldbus Parameter 17.1.1 Resource Block 2...
  • Page 139 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size (Bytes) MODE_BLK Writability Index Class RB2_BlockAlm Block Alarm Standard Dynamic RB2_BlockAlm_Unacknowledged Unacknowledged ENUM8 Dynamic AUTO RB2_BlockAlm_AlarmState Alarm State ENUM8 Dynamic RB2_BlockAlm_TimeStamp Time Stamp TimeValue Dynamic RB2_BlockAlm_SubCode...
  • Page 140 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size (Bytes) MODE_BLK Writability Index Class RB2_FdMaintActive Maintenance Active BIT_ENUM32 Dynamic RB2_FdCheckActive Check Active BIT_ENUM32 Dynamic RB2_FdFailMap Fail Map BIT_ENUM32 Static AUTO RB2_FdOffspecMap Offspec Map BIT_ENUM32 Static...
  • Page 141 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size (Bytes) MODE_BLK Writability Index Class RB2_FdSimulate_EnableDisable Simulate En/Disable ENUM8 Dynamic AUTO RB2_FdRecommenAct Recommended Action ENUM16 Dynamic RB2_HardwareVersion Hardware revision STRING Static RB2_FfCommVersion STRING Static RB2_RestartEnable Restart enable...
  • Page 142: Transducer Block Advanced Setup

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size (Bytes) MODE_BLK Writability Index Class RB2_FdRecommenAct Recommended Action ENUM16 Dynamic RB2_BlockErrDesc_1 Block error description BIT_ENUM32 Dynamic RB2_View4 Resource 2 View 4 VIEW4 Static RB2_StRev Static Revision...
  • Page 143 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDASUP_CollectionDirectory Collection Directory UINT32 Static TRDASUP_BlockErrDesc_1 Block error BIT_ENUM32 Dynamic description TRDASUP_STD_UserLevel_1 Access status ENUM16 Static tooling TRDASUP_STD_LockingState_1 Locking status BIT_ENUM16...
  • Page 144 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDASUP_PFS_StateSwitchOnDelay_1 Switch-on delay FLOAT Static AUTO TRDASUP_PFS_StateSwitchOffDelay_1 Switch-off delay FLOAT Static AUTO TRDASUP_PFS_StateFailsafeMode_1 Failure mode ENUM16 Static AUTO TRDASUP_PFS_StateOutValue_1 Switch status...
  • Page 145 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) SU_MassFlow Mass flow unit ENUM16 Static AUTO SU_Mass Mass unit ENUM16 Static AUTO SU_VolumeFlow Volume flow unit ENUM16 Static AUTO SU_Volume...
  • Page 146: Transducer Block Diagnostic

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) PFS_FrequencyMeasuringMode Measuring mode ENUM16 Static AUTO PFS_FrequencyDamping Damping output FLOAT Static AUTO PFS_FrequencyFailsafeMode Failure mode ENUM16 Static AUTO PFS_FrequencyFailsafeValue Failure frequency...
  • Page 147 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDDIAG_SPV_CurrentEventSpecificData_1 Actual diag UINT8 Static channel TRDDIAG_SPV_CurrentTimestamp_1 Timestamp STRING Static TRDDIAG_SPV_PreviousEventCategory_1 Event category ENUM8 Static TRDDIAG_SPV_PreviousEventId_1 Previous UINT16 Static diagnostics TRDDIAG_SPV_PreviousEventSpecificData_1...
  • Page 148 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDDIAG_VolumeFlowInput Volume flow Standard Dynamic TRDDIAG_Out2Status Status ENUM8 Dynamic FLOW_VolumeFlow Volume flow FLOAT Dynamic TRDDIAG_SU_VolumeFlow_1 Volume flow unit ENUM16 Static AUTO...
  • Page 149 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDDIAG_HB_InputSelector1_1 Assign channel 1 ENUM16 Static AUTO TRDDIAG_HB_InputSelector2_1 Assign channel 2 ENUM16 Static AUTO TRDDIAG_HB_InputSelector3_1 Assign channel 3 ENUM16 Static AUTO...
  • Page 150 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDDIAG_FF912StatusSelect_11 Assign status of ENUM8 Static AUTO diagnostic number TRDDIAG_FF912StatusSelect_12 Assign status of ENUM8 Static AUTO diagnostic number TRDDIAG_FF912StatusSelect_7 Assign status of...
  • Page 151 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDDIAG_SPV_EventClassDensityMonitoring_1 Assign behavior of ENUM16 Static AUTO diagnostic no. 862 TRDDIAG_SPV_EventClassFluidInhomogeneous_1 Assign behavior of ENUM16 Static AUTO diagnostic no. 912 TRDDIAG_SPV_EventClassOscAmpLimit_1...
  • Page 152 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) SPV_DiagItem3Timestamp Timestamp STRING Static TRDDIAG_FF912StatusSelect Assign status of ENUM8 Static AUTO diagnostic number TRDDIAG_FF912StatusSelect_2 Assign status of ENUM8 Static AUTO diagnostic number...
  • Page 153 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) SPV_OperationHoursSinceReset Operating time STRING Dynamic from restart SPV_OperationHours Operating time STRING Dynamic STD_LockingState Locking status BIT_ENUM16 Dynamic SPV_CurrentEventCategorySeparated Status signal ENUM8...
  • Page 154 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) SU_RefDensity Reference density ENUM16 Static AUTO unit SU_Pressure Pressure unit ENUM16 Static AUTO TRDDIAG_View4_2 View -4-1 VIEW4 Static TRDDIAG_StRev Static Revision...
  • Page 155: Transducer Block Display

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) SPV_EventClassElDynSensor Assign behavior of ENUM16 Static AUTO diagnostic no. 140 SPV_EventClassIncompHWConfiguration Assign behavior of ENUM16 Static AUTO diagnostic no. 252 SPV_EventClassZPCorrection...
  • Page 156 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDDISP_DISP_MainMeasFormat_1 Format display ENUM16 Static AUTO TRDDISP_DISP_InputSelector01_1 Value 1 display ENUM16 Static AUTO TRDDISP_DISP_DecimalPlaces01_1 Decimal places 1 ENUM16 Static AUTO TRDDISP_DISP_InputSelector02_1...
  • Page 157 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDDISP_SU_CorrVolumeFlow_1 Corrected volume ENUM16 Static AUTO flow unit TRDDISP_SU_Density_1 Density unit ENUM16 Static AUTO TRDDISP_SU_RefDensity_1 Reference density ENUM16 Static AUTO unit...
  • Page 158 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) DISP_IsBacklightAvailable Backlight ENUM16 Static AUTO DISP_IsCloneAvailable Is clone available UINT8 Static AUTO DISP_IsRestoreAvailable Is restore UINT8 Static AUTO available DISP_FixDisplayedInput ENUM16...
  • Page 159: Transducer Block Expert

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) DISP_Value03_100Percent 100% bargraph FLOAT Static AUTO value 3 SU_VolumeFlow Volume flow unit ENUM16 Static AUTO SU_MassFlow Mass flow unit ENUM16 Static...
  • Page 160 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDEXP_FLOW_VolumeFlowScale_1 Volume flow FLOAT Static AUTO factor TRDEXP_FLOW_CorrVolumeFlowOffset_1 Corrected volume FLOAT Static AUTO flow offset TRDEXP_FLOW_CorrVolumeFlowScale_1 Corrected volume FLOAT Static AUTO...
  • Page 161 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDEXP_TransducerType Transducer Type ENUM16 Static TRDEXP_XdError Transducer Error ENUM8 Dynamic TRDEXP_BlockErrDesc_1 Block error BIT_ENUM32 Dynamic description STD_LockingState Locking status BIT_ENUM16 Dynamic...
  • Page 162: Transducer Block Expert Info

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDEXP_StRev Static Revision UINT16 Static TRDEXP_Strategy Strategy UINT16 Static AUTO TRDEXP_AlertKey Alert Key UINT8 Static AUTO TRDEXP_TransducerType Transducer Type ENUM16 Static...
  • Page 163 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDEXPIN_SPV_PowerOnCounter_1 Power on UINT32 Static AUTO TRDEXPIN_STD_GeniXMLBuildNumber_1 XML build number UINT32 Static TRDEXPIN_CFM_EmergencyModeValidity_1 ENUM16 Static TRDEXPIN_CFM_SensorEmergencyMode_1 Activate sensor ENUM16 Static AUTO...
  • Page 164: Transducer Block Heartbeat

    Appendix Proline Promass E 200 FOUNDATION Fieldbus 17.1.7 Transducer Block Heartbeat Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBT_TransducerTypeVer UINT16 Static TRDHBT_XdError Transducer Error ENUM8 Dynamic TRDHBT_CollectionDirectory Collection UINT32 Static Directory TRDHBT_BlockErrDesc_1 Block error BIT_ENUM32...
  • Page 165: Counter

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBT_StRev Static Revision UINT16 Static TRDHBT_TransducerType Transducer Type ENUM16 Static STD_UserLevel Access status ENUM16 Static tooling STD_SWOptionActiveOverview Software option BIT_ENUM32 Static...
  • Page 166 Appendix Proline Promass E 200 FOUNDATION Fieldbus 17.1.8 Transducer Block Heartbeat Results 1 Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR1_TransducerTypeVer UINT16 Static TRDHBTR1_XdError Transducer ENUM8 Dynamic Error TRDHBTR1_CollectionDirectory Collection UINT32 Static Directory TRDHBTR1_BlockErrDesc_1 Block error...
  • Page 167 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR1_HBTR_InputOutputSlot2Data1Value_2 Output 2 FLOAT Static actual value 1 TRDHBTR1_HBTR_InputOutputSlot2Data1Result_2 Output 2 ENUM16 Static TRDHBTR1_HBTR_ExternVerificationFlags_2 External BIT_ENUM32 Static verification flags TRDHBTR1_HBTR_VerificationCarrTempSensorResult_1 Carrier tube...
  • Page 168 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR1_HBTR_MassFlowActual_1 Mass flow FLOAT Static verification value TRDHBTR1_HBTR_ElectronicTemperatureActual_1 Electronic FLOAT Static temperature TRDHBTR1_HBTR_CFMVoltages_1 Supply voltage FLOAT Static TRDHBTR1_HBTR_VerificationCarrTempSensorResult_2 Carrier tube ENUM16...
  • Page 169 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR1_HBTR_MassFlowActual_2 Mass flow FLOAT Static verification value TRDHBTR1_HBTR_ElectronicTemperatureActual_2 Electronic FLOAT Static temperature TRDHBTR1_HBTR_CFMVoltages_2 Supply voltage FLOAT Static TRDHBTR1_STD_LockingState_1 Locking status BIT_ENUM16 Dynamic...
  • Page 170 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_VerificationOverallResult Overall result ENUM16 Static HBTR_VerificationSensorResult Sensor ENUM16 Static HBTR_VerificationSensElectronicResult Main ENUM16 Static electronic module HBTR_VerificationInputOutputResult I/O module ENUM16 Static HBTR_VerificationSupplyVoltageResult...
  • Page 171 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_InputOutputSlot2Data1Value Output 2 FLOAT Static actual value 1 HBTR_InputOutputSlot2Data1Result Output 2 ENUM16 Static SU_VolumeFlow Volume flow ENUM16 Static AUTO unit SU_MassFlow...
  • Page 172 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_TemperatureActual Process FLOAT Static temperature verification value HBTR_MassFlowActual Mass flow FLOAT Static verification value HBTR_ElectronicTemperatureActual Electronic FLOAT Static temperature HBTR_VerificationProcTempSensResult Measuring...
  • Page 173: 17.1.9 Transducer Block Heartbeat Results

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_MassFlowActual Mass flow FLOAT Static verification value HBTR_ElectronicTemperatureActual Electronic FLOAT Static temperature 17.1.9 Transducer Block Heartbeat Results 2 Relative Name Label...
  • Page 174 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR2_HBTR_VerificationSensorSymmetryResult_3 Pickup coil ENUM16 Static symmetry TRDHBTR2_HBTR_VerificationSensorLeakageResult_3 Sensor circuit ENUM16 Static leakage TRDHBTR2_HBTR_VerificationLatSensorFreqResult_3 Frequency ENUM16 Static lateral mode TRDHBTR2_HBTR_VerificationZeroTrackingResult_3 Zero point...
  • Page 175 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR2_HBTR_VerificationSensElectronicResult_4 Main ENUM16 Static electronic module TRDHBTR2_HBTR_VerificationInputOutputResult_4 I/O module ENUM16 Static TRDHBTR2_HBTR_VerificationSupplyVoltageResult_4 Supply voltage ENUM16 Static TRDHBTR2_HBTR_ExternalDeviceInfo_4 External STRING Static device...
  • Page 176 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR2_HBTR_DampingActual_4 Damping FLOAT Static verification value TRDHBTR2_HBTR_DensityActual_4 Density FLOAT Static verification value TRDHBTR2_HBTR_TemperatureActual_4 Process FLOAT Static temperature verification value TRDHBTR2_HBTR_MassFlowActual_4 Mass flow...
  • Page 177 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_ExternVerificationFlags External BIT_ENUM32 Static verification flags HBTR_VerificationCarrTempSensorResult Carrier tube ENUM16 Static temperature sensor HBTR_VerificationLatSensorFreqResult Frequency ENUM16 Static lateral mode HBTR_VerificationDateTime Date/time...
  • Page 178 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_InputOutputSlot2Data1Value Output 2 FLOAT Static actual value 1 HBTR_InputOutputSlot2Data1Result Output 2 ENUM16 Static HBTR_ExternalDeviceInfo External STRING Static device information HBTR_InputOutputSlot2Type Slot 2 Modul...
  • Page 179 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_MeasCarrTubeTemp Carrier ENUM16 Static Temperature Measure supported HBTR_DampingActual Damping FLOAT Static verification value HBTR_DensityActual Density FLOAT Static verification value HBTR_TemperatureActual Process...
  • Page 180: 17.1.10 Transducer Block Heartbeat Results

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_DensityActual Density FLOAT Static verification value HBTR_TemperatureActual Process FLOAT Static temperature verification value HBTR_MassFlowActual Mass flow FLOAT Static verification value HBTR_ElectronicTemperatureActual...
  • Page 181 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR3_HBTR_VerificationCarrTempSensorResult_5 Carrier tube ENUM16 Static temperature sensor TRDHBTR3_HBTR_VerificationProcTempSensResult_5 Measuring ENUM16 Static tube temperature sensor TRDHBTR3_HBTR_VerificationSensorCoilResult_5 Pickup coil ENUM16 Static TRDHBTR3_HBTR_VerificationSensorSymmetryResult_5 Pickup coil...
  • Page 182 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR3_HBTR_VerificationDateTime_6 Date/time STRING Static TRDHBTR3_HBTR_VerificationCounter_6 Verification ID UINT16 Static TRDHBTR3_HBTR_OperationHours_6 Operating STRING Static time TRDHBTR3_HBTR_VerificationOverallResult_6 Overall result ENUM16 Static TRDHBTR3_HBTR_VerificationSensorResult_6 Sensor...
  • Page 183 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR3_HBTR_ReferenceClockDeviation_6 Reference FLOAT Static clock deviation TRDHBTR3_HBTR_ReferenceTempDeviation_6 Reference FLOAT Static temperature deviation TRDHBTR3_HBTR_MeasCarrTubeTemp_6 Carrier ENUM16 Static Temperature Measure supported TRDHBTR3_HBTR_DampingActual_6 Damping...
  • Page 184 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_VerificationOverallResult Overall result ENUM16 Static HBTR_VerificationSensorResult Sensor ENUM16 Static HBTR_VerificationSensElectronicResult Main ENUM16 Static electronic module HBTR_VerificationInputOutputResult I/O module ENUM16 Static HBTR_VerificationSupplyVoltageResult...
  • Page 185 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) STD_UserLevel Access status ENUM16 Static tooling STD_SWOptionActiveOverview Software BIT_ENUM32 Static option overview HBTR_ExternalDeviceInfo External STRING Static device information HBTR_InputOutputSlot2Type Slot 2 Modul...
  • Page 186 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_LateralSensorFreqDeviation Actual FLOAT Static frequency lateral mode HBTR_ReferenceClockDeviation Reference FLOAT Static clock deviation HBTR_ReferenceTempDeviation Reference FLOAT Static temperature deviation HBTR_MeasCarrTubeTemp Carrier...
  • Page 187: 17.1.11 Transducer Block Heartbeat Results

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_ReferenceTempDeviation Reference FLOAT Static temperature deviation HBTR_MeasCarrTubeTemp Carrier ENUM16 Static Temperature Measure supported HBTR_DampingActual Damping FLOAT Static verification value HBTR_DensityActual Density...
  • Page 188 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR4_HBTR_InputOutputSlot2Type_7 Slot 2 Modul ENUM16 Static Type TRDHBTR4_HBTR_InputOutputSlot2Data1Value_7 Output 2 FLOAT Static actual value 1 TRDHBTR4_HBTR_InputOutputSlot2Data1Result_7 Output 2 ENUM16 Static TRDHBTR4_HBTR_ExternVerificationFlags_7...
  • Page 189 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR4_HBTR_TemperatureActual_7 Process FLOAT Static temperature verification value TRDHBTR4_HBTR_MassFlowActual_7 Mass flow FLOAT Static verification value TRDHBTR4_HBTR_ElectronicTemperatureActual_7 Electronic FLOAT Static temperature TRDHBTR4_HBTR_CFMVoltages_7 Supply voltage...
  • Page 190 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR4_HBTR_VerificationReferenceTempResult_8 Reference ENUM16 Static temperature TRDHBTR4_HBTR_SensorSymmetryDeviation_8 Pickup coils FLOAT Static symmetry deviation TRDHBTR4_HBTR_ZeroTrackingDeviation_8 Zero point FLOAT Static tracking deviation TRDHBTR4_HBTR_LateralSensorFreqDeviation_8 Actual...
  • Page 191 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) STD_LockingState Locking status BIT_ENUM16 Dynamic TRDHBTR4_View2 View -2- VIEW2 Static TRDHBTR4_StRev Static Revision UINT16 Static TRDHBTR4_TransducerType Transducer ENUM16 Static Type HBTR_VerificationDateTime...
  • Page 192 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHBTR4_XdError Transducer ENUM8 Dynamic Error STD_LockingState Locking status BIT_ENUM16 Dynamic TRDHBTR4_View4 View -4- VIEW4 Static TRDHBTR4_StRev Static Revision UINT16 Static TRDHBTR4_Strategy...
  • Page 193 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_VerificationReferenceClockResult Reference ENUM16 Static clock HBTR_VerificationReferenceTempResult Reference ENUM16 Static temperature HBTR_SensorSymmetryDeviation Pickup coils FLOAT Static symmetry deviation HBTR_ZeroTrackingDeviation Zero point FLOAT...
  • Page 194: Transducer Block Historom

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) HBTR_ZeroTrackingDeviation Zero point FLOAT Static tracking deviation HBTR_LateralSensorFreqDeviation Actual FLOAT Static frequency lateral mode HBTR_ReferenceClockDeviation Reference FLOAT Static clock deviation HBTR_ReferenceTempDeviation...
  • Page 195 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHROM_HB_TrendStorageTime_1 Trend storage UINT32 Static time TRDHROM_HB_TrendSupportedPackageSize_1 UINT8 Static TRDHROM_HB_MaxTrendEntries_1 UINT16 Static TRDHROM_STD_CustomizedData_1 Customized UINT8 Static TRDHROM_STD_DeleteCustomizedData_1 Reset ordered ENUM16 Static...
  • Page 196 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHROM_F32Entry4 floatEntry 4 FLOAT Static AUTO TRDHROM_Trigger Trigger UINT8 Static AUTO TRDHROM_StatusPrepareCtrl Status Prepare Standard Static Ctrl TRDHROM_StatusTransactionId UINT8 Static TRDHROM_StatusBdtVersion...
  • Page 197 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHROM_TimeStamp3 STRING Static TRDHROM_EventId3 UINT16 Static TRDHROM_EventSpecificData3 UINT8 Static TRDHROM_EventCategory3 UINT8 Static TRDHROM_EventClass3 UINT8 Static TRDHROM_TimeStamp4 STRING Static TRDHROM_EventId4 UINT16 Static...
  • Page 198: Transducer Block Service Info

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDHROM_StRev Static Revision UINT16 Static TRDHROM_BlockErr Block Error BIT_ENUM16 Dynamic TRDHROM_TransducerType Transducer Type ENUM16 Static TRDHROM_XdError Transducer Error ENUM8 Dynamic TRDHROM_BlockErrDesc_1...
  • Page 199 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDSRVIF_MDI_ModuleAvailable_1 Resource UINT8 Static available TRDSRVIF_MDI_ModuleName_1 Module name STRING Static AUTO TRDSRVIF_MDI_ModuleSerialNumber_1 Serial number STRING Static AUTO TRDSRVIF_MDI_ModuleBootloaderRevision_1 Bootloader UINT32 Static...
  • Page 200 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDSRVIF_STD_LockingState_1 Locking status BIT_ENUM16 Dynamic TRDSRVIF_STD_SWOptionActiveOverview_1 Software option BIT_ENUM32 Static overview TRDSRVIF_View1 View -1- VIEW1 Dynamic TRDSRVIF_StRev Static Revision UINT16 Static...
  • Page 201: Transducer Block Service Sensor

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDSRVIF_Strategy Strategy UINT16 Static AUTO TRDSRVIF_AlertKey Alert Key UINT8 Static AUTO TRDSRVIF_TransducerType Transducer Type ENUM16 Static MDI_ModuleSerialNumber Serial number STRING Static...
  • Page 202 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDSRVSB_STD_LockingState_1 Locking status BIT_ENUM16 Dynamic TRDSRVSB_STD_SWOptionActiveOverview_1 Software option BIT_ENUM32 Static overview TRDSRVSB_CFM_DensityAdjustControl_1 Execute density ENUM16 Static AUTO adjustment TRDSRVSB_CFM_DensityAdjustState_1 ENUM16 Static...
  • Page 203 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDSRVSB_CFM_Frequency_1 Oscillation FLOAT Dynamic frequency TRDSRVSB_CFM_Amplitude_1 Oscillation FLOAT Dynamic amplitude TRDSRVSB_CFM_Damping_1 Oscillation FLOAT Dynamic damping TRDSRVSB_CFM_Asymmetry_1 Signal asymmetry FLOAT Dynamic TRDSRVSB_CFM_ElectronicsTemperature_1...
  • Page 204 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) SU_Density Density unit ENUM16 Static AUTO Dev_DateTimeFormat Date/time format ENUM16 Static AUTO Dev_NominalDiameter Nominal diameter STRING Static AUTO Dev_CalTimeString Calibration date/...
  • Page 205: Transducer Block Setup

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) CFM_DensityAdjustProgress Adjustment in FLOAT Static progress CFM_DensityAdjustSetValue1 Density setpoint 1 FLOAT Static AUTO CFM_DensityAdjustSetValue2 Density setpoint 2 FLOAT Static AUTO CFM_DensityFactor...
  • Page 206 Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDSUP_FLOW_RefDensityForcing_1 Corrected volume ENUM16 Static AUTO flow calculation TRDSUP_FLOW_ForcedRefDensity_1 Fixed reference FLOAT Static AUTO density TRDSUP_FLOW_LinearExpansionCoeff_1 Linear expansion FLOAT Static AUTO...
  • Page 207 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) CFM_GasType Select gas type ENUM16 Static AUTO CFM_RefSoundVelocity Reference sound FLOAT Static AUTO velocity CFM_TempCoeffSVel Temperature FLOAT Static AUTO coefficient sound...
  • Page 208: Transducer Block Total Inventory Counter

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) STD_LockingState Locking status BIT_ENUM16 Dynamic TRDSUP_View4 View -4- VIEW4 Static TRDSUP_StRev Static Revision UINT16 Static TRDSUP_Strategy Strategy UINT16 Static AUTO TRDSUP_AlertKey...
  • Page 209 Proline Promass E 200 FOUNDATION Fieldbus Appendix Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TRDTIC_STD_SWOptionActiveOverview_1 Software option BIT_ENUM32 Static overview TRDTIC_TIC_OverflowValue_3 Totalizer overflow FLOAT Dynamic AUTO TRDTIC_TIC_TotUnit_3 Unit totalizer ENUM16 Static AUTO TRDTIC_TIC_Control_3 Control Totalizer...
  • Page 210: Overview Of The Operating Menu

    Appendix Proline Promass E 200 FOUNDATION Fieldbus Relative Name Label Data type Storage Size MODE_BLK Writability Index Class (Bytes) TIC_FailsafeMode Failure mode ENUM16 Static AUTO TIC_SumMode Totalizer operation ENUM16 Static AUTO mode TIC_Channel Assign process ENUM16 Static AUTO variable TIC_TotUnit...
  • Page 211: Operation" Menu

    Proline Promass E 200 FOUNDATION Fieldbus Appendix 17.2.1 "Operation" menu Navigation  Operation Operation (→  86) Access status display Locking status ‣ Display (→  60) Format display (→  61) Contrast display Backlight (→  77) Display interval (→...
  • Page 212 Appendix Proline Promass E 200 FOUNDATION Fieldbus Corrected volume unit (→  57) Density unit (→  57) Reference density unit (→  57) Temperature unit (→  57) (→  57) Length unit Pressure unit (→  57) ‣...
  • Page 213 Proline Promass E 200 FOUNDATION Fieldbus Appendix Value 3 display (→  62) 0% bargraph value 3 (→  62) 100% bargraph value 3 (→  62) Value 4 display (→  62) ‣ Low flow cut off (→  63) Assign process variable (→...
  • Page 214 Appendix Proline Promass E 200 FOUNDATION Fieldbus Assign diagnostic behavior (→  72) Assign limit (→  73) Assign flow direction check (→  73) Assign status (→  73) (→  70) Mass flow unit Mass unit (→  68) Volume flow unit (→...
  • Page 215 Proline Promass E 200 FOUNDATION Fieldbus Appendix Maximum frequency value (→  70) Measuring value at minimum (→  70) frequency Measuring value at maximum (→  70) frequency (→  71) Failure mode (→  71) Failure frequency Switch-on value (→...
  • Page 216 Appendix Proline Promass E 200 FOUNDATION Fieldbus Value 3 display (→  62) 0% bargraph value 3 (→  62) 100% bargraph value 3 (→  62) Decimal places 3 (→  76) (→  62) Value 4 display Decimal places 4 (→...
  • Page 217: Diagnostics" Menu

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Configuration management (→  78) Comparison result (→  78) ‣ Administration ‣ Define access code (→  80) Define access code Confirm access code Restart 17.2.3 "Diagnostics" menu Navigation  Diagnostics Diagnostics (→...
  • Page 218 Appendix Proline Promass E 200 FOUNDATION Fieldbus ‣ Device information (→  107) Device tag (→  107) Serial number (→  107) Firmware version (→  108) (→  108) Order code Extended order code 1 (→  108) Extended order code 2 (→...
  • Page 219 Proline Promass E 200 FOUNDATION Fieldbus Appendix ‣ Analog inputs (→  60) ‣ Analog input 1 to 6 Block tag (→  60) Channel (→  60) Status Value Units index ‣ Digital inputs ‣ Digital input 1 to 2...
  • Page 220 Appendix Proline Promass E 200 FOUNDATION Fieldbus ‣ Heartbeat ‣ Performing verification Year Month Hour AM/PM Minute Verification mode External device information Start verification Status Measured values Output values Overall result ‣ Verification results Date/time Verification ID Operating time Overall result...
  • Page 221: Expert" Menu

    Proline Promass E 200 FOUNDATION Fieldbus Appendix Value process variable (→  79) Frequency simulation (→  79) Frequency value (→  79) Pulse simulation (→  79) Pulse value (→  80) Switch output simulation (→  80) Switch status (→...
  • Page 222 Appendix Proline Promass E 200 FOUNDATION Fieldbus ‣ Discrete inputs (→  233) ‣ Analog outputs (→  233) ‣ Discrete outputs (→  234) ‣ Application (→  234) ‣ (→  235) Diagnostics "System" submenu Navigation  Expert → System System ‣...
  • Page 223 Proline Promass E 200 FOUNDATION Fieldbus Appendix Display damping (0094) (→  77) Header (0097) (→  77) Header text (0112) (→  77) Separator (0101) (→  77) Contrast display (0105) Backlight (0111) (→  77) Access status display (0091) ‣...
  • Page 224 Appendix Proline Promass E 200 FOUNDATION Fieldbus Assign behavior of diagnostic no. 830 (0715) Assign behavior of diagnostic no. 831 (0716) Assign behavior of diagnostic no. 832 (0675) Assign behavior of diagnostic no. 833 (0676) Assign behavior of diagnostic no. 834 (0677) Assign behavior of diagnostic no.
  • Page 225 Proline Promass E 200 FOUNDATION Fieldbus Appendix Assign status of diagnostic number 835 (11005) Assign status of diagnostic number 862 (11008) Assign status of diagnostic number 912 (11009) Assign status of diagnostic number 913 (11010) ‣ Administration ‣ Define access code (→...
  • Page 226 Appendix Proline Promass E 200 FOUNDATION Fieldbus ‣ Totalizer (→  74) Totalizer value 1 to 3 (0911–1 to 3) (→  87) Totalizer overflow 1 to 3 (0910–1 to 3) (→  87) ‣ Output values (→  88) (→...
  • Page 227 Proline Promass E 200 FOUNDATION Fieldbus Appendix Temperature damping (1807) ‣ Low flow cut off (→  63) Assign process variable (1837) (→  63) On value low flow cutoff (1805) (→  63) Off value low flow cutoff (1804) (→...
  • Page 228 Appendix Proline Promass E 200 FOUNDATION Fieldbus Linear expansion coefficient (1817) (→  68) Square expansion coefficient (1818) (→  68) ‣ Sensor adjustment (→  66) Installation direction (1809) (→  66) ‣ Zero point adjustment Zero point adjustment control (2587) Adjustment in progress (2588) (→...
  • Page 229 Proline Promass E 200 FOUNDATION Fieldbus Appendix Reference density factor (1827) Temperature offset (1830) Temperature factor (1829) ‣ Calibration Calibration factor (2431) Zero point (2437) Nominal diameter (2807) C 0 (2469) C 1 (2574) C 2 (2575) C 3 (2576)
  • Page 230 Appendix Proline Promass E 200 FOUNDATION Fieldbus AM/PM (2813) Minute (2844) Confirm settings (2847) ‣ Logbook Calibration counter (2820) Select calibration log entry (2823) Timestamp (2824) Calibration factor (2825) ‣ Testpoints Oscillation frequency (2515) Oscillation amplitude (2516) Oscillation damping (2517)
  • Page 231 Proline Promass E 200 FOUNDATION Fieldbus Appendix Assign frequency output (0478) (→  70) Minimum frequency value (0453) (→  70) Maximum frequency value (0454) (→  70) Measuring value at minimum (→  70) frequency (0476) Measuring value at maximum (→...
  • Page 232 Appendix Proline Promass E 200 FOUNDATION Fieldbus Communication Device address (11061) ‣ Resource block Block tag (10702) Target mode (10728) Actual mode (10725) Manufacturer Id (10721) Device Type (10711) (→  108) Device Revision (10710) (→  108) DD Revision (10709)
  • Page 233 Proline Promass E 200 FOUNDATION Fieldbus Appendix Discrete inputs ‣ Discrete input 1 to 2 Block tag (6851–1 to 2) Status (6853–1 to 2) Value (6854–1 to 2) Channel (6852–1 to 2) Process Value Filter Time (6855–1 to 2) Analog outputs ‣...
  • Page 234 Appendix Proline Promass E 200 FOUNDATION Fieldbus Discrete outputs ‣ Multiple discrete output Block tag (11252) Status Options (11268) Fault State Time (11255) Fault State Value Discrete 1 (11256) Fault State Value Discrete 2 (11257) Fault State Value Discrete 3 (11258)
  • Page 235 Proline Promass E 200 FOUNDATION Fieldbus Appendix Preset value 1 to 3 (0913–1 to 3) (→  89) Failure mode (0901–1 to 3) (→  74) ‣ Inventory counter Totalizer value (0971) Totalizer overflow (0972) Diagnostics (→  103) Actual diagnostics (0691) (→...
  • Page 236 Appendix Proline Promass E 200 FOUNDATION Fieldbus Device Revision (10710) (→  108) DD Revision (10709) Firmware version (10792) (→  108) Hardware revision (10793) ITK Version (10794) Order code (10795) (→  108) Extended order code 1 (10796) (→  108) Extended order code 2 (10797) (→...
  • Page 237 Proline Promass E 200 FOUNDATION Fieldbus Appendix Serial number (0071) Bootloader revision (0073) ‣ Display module Software revision (0072) Build no. software (0079) Hardware revision (0074) Module name (0077) Serial number (0071) Bootloader revision (0073) ‣ Data logging (→  89) Assign channel 1 (0851) (→...
  • Page 238 Appendix Proline Promass E 200 FOUNDATION Fieldbus Maximum value (0663) Average value (0698) ‣ Main electronic temperature Minimum value (2457) Maximum value (2456) ‣ IO module temperature Minimum value (0688) Maximum value (0665) Average value (0697) ‣ Medium temperature Minimum value (2502) Maximum value (2501) ‣...
  • Page 239 Proline Promass E 200 FOUNDATION Fieldbus Appendix ‣ Oscillation damping Minimum value (2586) Maximum value (2585) ‣ Signal asymmetry Minimum value (2551) Maximum value (2476) ‣ Heartbeat ‣ Heartbeat base settings Plant operator (2754) Location (2755) ‣ Performing verification Year (2846)
  • Page 240 Appendix Proline Promass E 200 FOUNDATION Fieldbus Output values (12103) Overall result (12149) ‣ Verification results Date/time (12142) Verification ID (12141) Operating time (12126) Overall result (12149) Sensor (12152) Main electronic module (12151) I/O module (12145) ‣ Simulation (→  78) Assign simulation process variable (→...
  • Page 241: Index

    Proline Promass E 200 FOUNDATION Fieldbus Index Index Define access code ......81 Degree of protection ..... 31, 126 Access authorization to parameters Density .
  • Page 242 Index Proline Promass E 200 FOUNDATION Fieldbus Electrical connection Hardware write protection ..... 81 Commubox FXA291 ..... . . 46 Help text Degree of protection .
  • Page 243 Proline Promass E 200 FOUNDATION Fieldbus Index Manufacturing date ..... . . 14, 15 Materials ....... . 129 Operable flow range .
  • Page 244 Index Proline Promass E 200 FOUNDATION Fieldbus Pressure-temperature ratings ....127 Sensor adjustment ......66 Process connections .
  • Page 245 Proline Promass E 200 FOUNDATION Fieldbus Index For wizard ......36 Low flow cut off .
  • Page 246 www.addresses.endress.com...

Table of Contents