Endress+Hauser Proline Promass E 500 PROFINET Operating Instructions Manual page 273

Coriolis flowmeter
Table of Contents

Advertisement

Proline Promass E 500 PROFINET
Endress+Hauser
Cable entries and adapters
Cable gland M20 × 1.5
• Adapter for cable entry with internal thread G ½"
• Adapter for cable entry with internal thread NPT ½"
Only available for certain device versions:
• Order code for "Transmitter housing":
• Option A "Aluminum, coated"
• Option D "Polycarbonate"
• Order code for "Sensor connection housing":
• Proline 500 – digital:
Option A "Aluminum coated"
Option B "Stainless"
• Proline 500:
Option B "Stainless"
Connecting cable
UV rays can impair the cable outer sheath. Protect the cable from exposure to sun as
much as possible.
Connecting cable for sensor - Proline 500 – digital transmitter
PVC cable with copper shield
Connecting cable for sensor - Proline 500 transmitter
• Standard cable: PVC cable with copper shield
• Reinforced cable: PVC cable with copper shield and additional steel wire braided jacket
Sensor housing
• Acid and alkali-resistant outer surface
• Stainless steel 1.4301 (304)
Measuring tubes
Stainless steel, 1.4539 (904L); manifold: stainless steel, 1.4404 (316L)
Process connections
• Flanges according to EN 1092-1 (DIN2501) / according to ASME B 16.5 / as per JIS
B2220:
Stainless steel, 1.4404 (F316/F316L)
• All other process connections:
Stainless steel, 1.4404 (316/316L)
Available process connections→  274
Seals
Welded process connections without internal seals
Accessories
Protective cover
Stainless steel, 1.4404 (316L)
Technical data
Material
Plastic
Nickel-plated brass
273