Operating Philosophy - Endress+Hauser Proline Promass E 500 PROFINET Operating Instructions Manual

Coriolis flowmeter
Table of Contents

Advertisement

Operation options
Menu/parameter
Language
task-oriented
Operation
Setup
Diagnostics
Expert
function-oriented
70
8.2.2

Operating philosophy

The individual parts of the operating menu are assigned to certain user roles (operator,
maintenance etc.). Each user role contains typical tasks within the device lifecycle.
User role and tasks
Role "Operator", "Maintenance"
Tasks during operation:
• Configuring the operational
display
• Reading measured values
"Maintenance" role
Commissioning:
• Configuration of the
measurement
• Configuration of the inputs and
outputs
• Configuration of the
communication interface
"Maintenance" role
Fault elimination:
• Diagnostics and elimination of
process and device errors
• Measured value simulation
Tasks that require detailed
knowledge of the function of the
device:
• Commissioning measurements
under difficult conditions
• Optimal adaptation of the
measurement to difficult
conditions
• Detailed configuration of the
communication interface
• Error diagnostics in difficult cases
Content/meaning
• Defining the operating language
• Defining the Web server operating language
• Resetting and controlling totalizers
• Configuring the operational display (e.g. display format, display contrast)
• Resetting and controlling totalizers
Wizards for fast commissioning:
• Setting the system units
• Configuration of the communication interface
• Defining the medium
• Displaying the I/O/configuration
• Configuring the inputs
• Configuring the outputs
• Configuration of the operational display
• Setting the low flow cut off
• Configuring partial and empty pipe detection
Advanced setup
• For more customized configuration of the measurement (adaptation to
special measuring conditions)
• Configuration of totalizers
• Configuring the WLAN settings
• Administration (define access code, reset measuring device)
Contains all parameters for error detection and analyzing process and device
errors:
• Diagnostic list
Contains up to 5 currently pending diagnostic messages.
• Event logbook
Contains event messages that have occurred.
• Device information
Contains information for identifying the device.
• Measured values
Contains all current measured values.
• Data logging submenu with "Extended HistoROM" order option
Storage and visualization of measured values
• Heartbeat
The functionality of the device is checked on demand and the verification
results are documented.
• Simulation
Is used to simulate measured values or output values.
Contains all the parameters of the device and makes it possible to access
these parameters directly using an access code. The structure of this menu is
based on the function blocks of the device:
• System
Contains all higher-order device parameters which do not concern the
measurement or the communication interface.
• Sensor
Configuration of the measurement.
• Input
Configuration of the status input.
• Output
Configuration of the analog current outputs as well as the pulse/frequency
and switch output.
• Communication
Configuration of the digital communication interface and the Web server.
• Application
Configuration of the functions that go beyond the actual measurement
(e.g. totalizer).
• Diagnostics
Error detection and analysis of process and device errors and for device
simulation and Heartbeat Technology.