Electrical connection
36
Relay output
Standard installation cable is sufficient.
Current input 0/4 to 20 mA
Standard installation cable is sufficient.
Status input
Standard installation cable is sufficient.
Cable diameter
• Cable glands supplied:
M20 × 1.5 with cable ⌀ 6 to 12 mm (0.24 to 0.47 in)
• Spring-loaded terminals: Suitable for strands and strands with ferrules.
Conductor cross-section 0.2 to 2.5 mm
Choice of connecting cable between the transmitter and sensor
Depends on the type of transmitter and the installation zones
4
1
A
3
5
6
1
Proline 500 digital transmitter
2
Proline 500 transmitter
3
Sensor Promass
4
Non-hazardous area
5
Hazardous area: Zone 2; Class I, Division 2
6
Hazardous area: Zone 1; Class I, Division 1
A
Standard cable to 500 digital transmitter →  37
Transmitter installed in the non-hazardous area or hazardous area: Zone 2; Class I, Division 2 / sensor
installed in the hazardous area: Zone 2; Class I, Division 2
B
Standard cable to 500 digital transmitter →  37
Transmitter installed in the hazardous area: Zone 2; Class I, Division 2 / sensor installed in the hazardous
area: Zone 1; Class I, Division 1
C
Signal cable to 500 transmitter →  39
Transmitter and sensor installed in the hazardous area: Zone 2; Class I, Division 2 oder Zone 1;
Class I, Division 1
2
(24 to 12 AWG).