Diagnostic Of Process - Endress+Hauser Proline Promass E 500 PROFINET Operating Instructions Manual

Coriolis flowmeter
Table of Contents

Advertisement

Diagnostics and troubleshooting
Diagnostic information
No.
537 Configuration
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
Diagnostic information
No.
594 Relay output simulation
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
Diagnostic information
No.
803 Current loop
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
226
Short text
Good
Ok
0x80 to 0x83
F
Warning
Short text
Good
Ok
0x80 to 0x83
C
Warning
12.7.4

Diagnostic of process

Short text
Good
Ok
0x80 to 0x83
F
Alarm
Remedy instructions
1. Check IP addresses in network
2. Change IP address
Remedy instructions
Deactivate simulation switch output
Remedy instructions
1. Check wiring
2. Change I/O module
Proline Promass E 500 PROFINET
Endress+Hauser