Technical data
12.1
DC geared motor
Supply voltage
Maximum speed
Degree of protection
Gear ratio
Pulse generator
Rated current
12.2
Control unit
Supply voltage
Relative symmetrical tolerance of the supply voltage
Tolerance
On-site protection
Maximum power consumption
Degree of protection
Control inputs
Door width
Maximum counterweight
Output relay switching capacity
Max. perm. storage temperature
Max. perm. operating temperature
Pollution degree
Moisture requirement
Installation altitude above MSL
24 V output
Use
Operating altitude
Overvoltage category
Pollution degree
26
24 VDC
0.5 m/s
IP 21
15:1
100 pulses/revolution
1.8 A
230 V, 50/60 Hz
±15 %
±15 %
6 A to 10 A (I²t > 30 A²s)
1 A
IP 20
+10 V DC to +28 V DC, 6 mA to 18 mA per input (floating, p
switching)
0.3 m to 2.40 m
4 kg
30 VDC, 0.5 A (10 mA min.)
- 20 to + 85°C
- 0 to + 50°C
2
No condensation
2 000 m
Max. output current 120 mA, short-circuit and overload-
proof
CAUTION: Do not supply with external voltage!
For indoor use only
Up to 2 000 m
II
2
Equipment Manual, 06/2020, A2B00086683-AD
12
Elevator door drive AT12