Pinnacle™ 20 kW
In a master/slave system, the out-of-setpoint limit is 3.125% of full scale, and it is
applied to the entire output of the master/slave system.
Note: The master of a master/slave system is also constrained by the stand-alone out-
of-setpoint limit. This limit (0.4% of full scale or 2.0% of setpoint) only applies
to the output of the master in the system.
When an out-of-setpoint condition occurs, the unit shuts off output and displays error
code E001: OUT OF SETPOINT TIMER EXPIRED. (See the "Error Codes" section
of the "Troubleshooting" chapter for more information about error codes).
To enable the out-of-setpoint timer, follow these steps to select a value (in 0.1 s
increments); to disable the timer, follow these steps and select a value of 0:
Note: Because the readbacks, which are compared to the setpoint, are filtered in the
software, we recommend you do not use this feature for process runs that are
less than 1.0 s.
1. Press PROCESS → MONITOR→ SETPT.
2. Rotate the MODIFY knob to adjust the value.
3. Press ENTER to accept and exit.

CHANGING THE TARGET FUNCTIONS

PROCESS → MONITOR→ TARGET
The target functions let you enable or disable the target life counter (ENABLE),
change the active target (SELECT), and set the target life (LIFE) in 0.01 KWh
increments.
PROCESS → MONITOR→ TARGET → ENABLE
To enable or disable the target life counter for the selected target:
1. Press PROCESS → MONITOR → TARGET → ENABLE.
2. Rotate the Modify knob to select Yes or No.
3. Press ENTER to accept and exit.
PROCESS → MONITOR→ TARGET → SELECT
To change the active target life counter:
1. Press PROCESS → MONITOR → TARGET → SELECT.
2. Rotate the MODIFY knob to select the active target number.
3. Press ENTER to accept and exit.
Note: The User port has priority in selecting targets. Thus, if your unit has a user
5702156-E
card installed, you must set the target to 1 at the User port if you want to
select targets from the serial port, active front panel, or Pinnacle Remote
I/O Communication and Control
4-33