FUNCTIONAL SPECIFICATIONS

Table 3-1. Functional Specifications
Modes of Control
Passive Panel Options
Method of Output
Regulation
Programmable
Setpoints
Output Limits
Target Supervision
5702156-E
Pinnacle™ 20 kW
Serial communications (Host) port, User port
(analog/digital interface), active front panel, and/or
Pinnacle Remote Active Panel
Your unit also may feature either a passive front
panel or a remote passive panel.
The regulation mode is the parameter that remains
constant when the Pinnacle is producing output; it
can be power, current, or voltage. Select one of
these regulation modes from the optional Pinnacle
Remote Active Panel, the active front panel, the
User port, or the serial (Host) port.
You can program an output level (from low values
up to the unit's maximum rates of output) for
power, current, or voltage. Select this value from
the optional Pinnacle Remote Active Panel, the
active front panel, the User port, or the serial
(Host) port.
You may set maximum output limits for power,
voltage, and current. You also may select a
maximum strike-voltage range. Select these values
from the optional Pinnacle Remote Active Panel,
the active front panel, the User port, or the serial
(Host) port.
You can select one of eight target-life counters
from the active front panel, Pinnacle Remote
Active Panel, User port, or serial (Host) port.
Target life can be monitored from the Pinnacle
Remote Active Panel, the active front panel, and
the serial port.
Note: The User port has priority when selecting
targets.