iLS600, iLS600-R and iLS1500 Series
SECTION 6
STATUS AND ERRORS
SCPI Access
To view the Error Condition Register, use the SCPI command:
SYSTem:ERRor:CONDition? Return the error condition register
6.0.16 Status Byte Register and Service Request Enable Register
Figure 7 shows the Status Byte Register and the Service Request Enable Register.
Figure 7: Status Byte Register
The six individual condition inputs of the Status Byte Register are:
Error/Event Queue
When the Error/Event Queue contains one or more entries, this bit will be set.
Questionable Status
If a Questionable Event has occurred and is enabled to feed the Status Byte Register, this
bit will be set.
advancedenergy.com
32
Rev. 05.20.21_#1.0