Servicing The Battery; Remove The Battery - Oracle Exadata X10M Service Manual

Table of Contents

Advertisement

10

Servicing the Battery

This section describes how to service the system battery.
The system battery is a replaceable component that requires you to power off the server
before servicing. For more information about replaceable components, see
Breakdown
The real-time clock (RTC) battery maintains system time when the server is powered off and
a time server is unavailable. If the server does not maintain the correct time when the system
is powered off and not connected to a network, replace the battery.
Caution:
These procedures require that you handle components that are sensitive to
electrostatic discharge. This sensitivity can cause the components to fail. To avoid
damage, ensure that you follow antistatic practices, as described in
Discharge
Caution:
Ensure that all power is removed from the server before removing or installing the
battery. You must disconnect the power cables from the system before performing
this procedure.

Remove the Battery

Battery holder types may vary.
Prepare the server for service.
1.
a.
b.
c.
d.
e.
Locate the battery and RTC battery retainer on the server motherboard.
2.
and
Replaceable
Components.
Safety.
Power off the server.
See
Powering Down the
Server.
Disconnect the power cords from the power supplies.
See
Disconnect Cables From the
Extend the server into the maintenance position.
See
Extend the Server to the Maintenance
Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.
See
Take Antistatic
Measures.
Remove the server top cover.
See
Remove the Server Top
Server.
Position.
Cover.
Illustrated Parts
Electrostatic
10-1

Advertisement