See
Powering Down the
Disconnect the power cords from the power supplies.
b.
See
Disconnect Cables From the
Extend the server into the maintenance position.
c.
See
Extend the Server to the Maintenance
Attach an antistatic wrist strap to your wrist and then to a metal area on the chassis.
d.
See
Take Antistatic
Remove the server top cover.
e.
See
Remove the Server Top
Remove the air baffle.
f.
See
Remove the Air
Identify and note the location of the failed DIMM by pressing the Fault Remind button on
2.
the motherboard.
See
Using the Server Fault Remind
Failed DIMMs are identified with a corresponding amber LED on the motherboard.
If the DIMM Fault LED is off, then the DIMM is operating properly.
If the DIMM Fault LED is on (amber), then the DIMM is failed and must be replaced
[1].
To remove the failed DIMM, do the following:
3.
Rotate both DIMM slot ejectors outward as far as they go.
a.
The DIMM is partially ejected from the slot.
Carefully lift the DIMM straight up to remove it from the slot.
b.
Server.
Server.
Position.
Measures.
Cover.
Baffle.
Button.
Chapter 9
Identify and Remove a DIMM
9-7

Advertisement

Table of Contents
loading