Servicing The Battery; Replace The Battery - Oracle SPARC T7-4 Service Manual

Hide thumbs Also See for SPARC T7-4:
Table of Contents

Advertisement

Servicing the Battery

The battery is a cold-service component that can be replaced by a customer. For the location of
the battery, see
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause failure of server components.
"Replace the Battery" on page 137
"Verify the Battery" on page 140

Replace the Battery

1.
Prepare the host for battery replacement.
To correctly reset the date and time before replacing a battery, you must revent the host from
automatically powering on and disable any NTP connections.
a.
Check the HOST_AUTO_POWER_ON property.
-> show /SP/policy HOST_AUTO_POWER_ON
Properties:
HOST_AUTO_POWER_ON = enabled
b.
If enabled, set the HOST_AUTO_POWER_ON property to disabled.
-> set /SP/policy HOST_AUTO_POWER_ON=disabled
c.
Check the NTP policy for the /SP/clock.
-> show /SP/clock usentpserver
Properties:
usentpserver = enabled
d.
If enabled, set the property to disabled.
-> set /SP/clock usentpserver=disabled
"Processor Module Components" on page
19.
Servicing the Battery
137