Mitsubishi Electric MELSERVO HF-MP Instruction Manual page 298

Servo motor
Table of Contents

Advertisement

10. HC-UP SERIES
Note 1. When the power supply voltage drops, we cannot guarantee the out put and rated speed.
2. If the load inertia moment ratio exceeds the indicated value, please consult your local sales office.
3. Refer to the outline dimension drawing for the servo motor with an electromagnetic brake.
4. Except for the shaft – through portion.
5. In the environment where the servo motor is exposed to oil mist, oil and/or water, the servo motor of the standard specifications
may not be usable. Contact your local sales office.
6. The vibration direction is as shown in the figure. The value is the one at the part that indicates the maximum value (normally the
opposite-to-load side bracket). When the servo motor stops, fretting is likely to occur at the bearing. Therefore, suppress the
vibration to about half of the permissible value.
Servo motor
X
Y
Vibration
7. V10 indicates that the amplitude of a single servo motor is 10 m or less. The following figure shows the servo motor installation
position for measurement and the measuring position.
Servo motor
Top
Measuring position
Bottom
8. For the symbols in the table, refer to the following diagram: Do not subject the shaft to load greater than this value.
L
1000
100
10
0 1000 2000 3000
Speed [r/min]
Radial load
L: Distance from flange mounting surface to load center
Thrust load
3450
The values in the table assume that the loads work singly.
10 - 3

Advertisement

Table of Contents
loading