Connecting Readers; M-In/Out Programmable Input/Output Expander16 - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

n Connecting Readers
Readers can be located in places where limited control
of the system is required (Arming, A and B Mode Arm-
ing, Disarming and Stop Alarm operations).
This system supports Digital Key and Proximity Card
Readers.
Key Readers Key Readers can be flush mounted to
most standard domestic light-switch/plug-socket outlet
boxes. Ask your dealer or go to the available covers on
site www.bentelsecurity.com.
+
Digital Key Readers must be at least 10 cm apart.
To install Key Readers, work carefully through the fol-
lowing steps (see Figure on page 13).
1. Assign the Reader Address, then set the BPI Level
and complete the connections on the terminal
board (refer to "Connecting BPI Peripherals" for in-
structions).
2. Fit the Reader in its placement (use the standard
procedure for fitting domestic light-switches and
plug sockets).
Proximity Readers Proximity Readers can be surface
mounted, or mounted to Mod. 503 outlet boxes or simi-
lar. Proximity Readers are fitted with weather strips
(Protection Class IP34), therefore, are suitable for out-
door use.
+
Proximity Readers must be at least 50 cm apart.
To install Proximity Readers, work carefully through the
following steps (see Figure on page 13).
3. Remove the screw 90 (if fitted), then using a screw-
driver or similar tool push down on the catch 93 to
release the frontplate.
Figure 9 Mounting Key Readers ECLIPSE2 Magic
type
16
4. Drill the holes for the backplate and Seize
microswitch bracket anchor screws (83 and 88 re-
spectively).
5. If you are fitting a Seize microswitch (Order Code:
ASNC-MINI), push it firmly into its location (87 in
Fig. 6) then connect it to the connector 86. Ensure
that the Seize microswitch lever is held firmly in po-
sition by the bracket tooth.
6. Secure the Reader and Seize microswitch bracket
to the wall.
7. Assign the Reader Address, set the BPI Level and
complete the connections on the terminal board
(refer to "Connecting BPI Peripherals" for instruc-
tions).
8. Reattach the frontplate.
n M-IN/OUT Programmable Input/Output Expander
Fix the M-IN/OUT Input/Output Expander as close as
possible to the devices to which it is to be connected.
The Expander is provided with a plastic container for
visible (surface) mounting or flush mounting, as de-
scribed in the following instructions (see Figure on
page 14).
1. Remove the knockout (103 or 105 as required).
2. – Surface mounting: drill the holes for the backplate
and Seize microswitch bracket anchor screws (106
and 107 respectively).
– Flush mounting to Mod. 503 outlet box or similar:
drill the hole for the Seize microswitch bracket an-
chor screw 104. No other drilling is required for
Flush mounting.
3. Pull the wires through the wire entry.
4. Secure the back box and Seize microswitch
bracket to the wall.
+
Position the snatch microswitch bracket as shown
in figure 8 on page 14, with the conductive pin 109
on the back of the container. The pin is designed to
close the snatch microswitch contact 96 on the
printed circuit (solder side).
5. Replace the PCB inside the box.
6. Set the Address of the device and carry out the con-
nections on terminal board 72, as described in the
paragraph "Connecting the BPI devices".
7. Set the operating mode for the tamper switch and
snatch microswitch using jumper 97:
To the
oo = Tamper and Snatch switches enabled ;
tamper line
// = Tamper and Snatch switches disabled.
KYO 320

Advertisement

Table of Contents
loading