ALL the AND-Zones detect violation within the set time.
Press ENTER to go back to step 3.
PROGRAMMING
Configuration

Outputs

From the PROGRAMMING menu:
PROGRAMMING
Configuration
1. Using A or B, select the Outputs option.
PROGRAMMING
Outputs
2. Press ENTER.
Output
n.
001
Output
001
3. Using A or B, select the Output to be programmed
then press.
Description
Output
001
4. Enter the Output label (refer to "Editing a text" under
"Using the Keypad"), then press ENTER.
Output
001
Monostable
5.Using A or B, select the Output Type (Monostable or
Bistable), then press ENTER.
Output
001
Superv.norm.clo
6.Using A or B, select the Output Polarity: Su-
perv.norm.clo (refer to "Normally closed" and "Super-
vised"), Normally open or Normally closed, then
press ENTER.
+
Only Outputs 1, 2 and 3 of KYO 320 can be pro-
grammed as Superv.norm.clo.
Follow
n.
---
None
7.Enter the ID number of the Output which will be trac-
ked by the Output concerned. Enter all zeros if the Out-
4 Outputs relating to M-IN/OUT expanders programmed as Input and Output Expanders are NOT all usable, even if they
are shown on the display. For example, if Output Expander no. 1 is an M-IN/OUT Expander programmed as an
Expander with 4 Zones + 2 Outputs, Outputs 07, 08, 09 and 10 are NOT usable. In general, Outputs [3+(x*6)],
[3+(x*6)], [5+(x*6)] and [6+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Zones + 2 Outputs, and
Outputs [5+(x*6)] and [6+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Outputs + 2 Zones, where
"x" is the address of the Expander, are NOT usable.
KYO320
put is not to track another Output.
The keypad will emit an audible error signal, if you:
Ø attempt to program a value other than "None" for an
Output which is associated with an event;
Øattempt to program an Output which has been pro-
grammed to track another Output;
Øattempt to program the selected Output.
Press ENTER.
Options
Reserved
8. Using ON or OFF, enable/disable the Reserved attri-
bute ("û" means enabled, and "-" disabled).
+
The Reserved and Follow No. attributes exclude
each other automatically. The Reserved Outputs
cannot be associated with events.
Press ENTER:
Ass.timer n. ---
None
4
,
9. Using A or B, select the Timer which will control the
Output, then press ENTER:
ON
Min.
10. Using A or B, select Minutes or Seconds for the ON
time, then enter the ON time for the Output. Valid en-
tries: 0.2 to 25.4 seconds in steps of 0.2 or 1 through
127 minutes in steps of 1 minute.
Press ENTER.
Off
time
Sec.
11. Enter the amount of time that must elapse (after
Output restoral) before the Output can be reactivated.
The OFF time can be set for Monostable Outputs
ONLY. Valid entries: 1 through 255 seconds in steps of
1 second.
Press ENTER:
Oscillation
None
12. Using A or B, select the Half Cycle of the oscilla-
tion. The Output will activate for the programmed time,
restore to standby for the same amount of time, and
then reactivate.
Valid entries: 200 through 1400 msec (milliseconds;
1000 msec = 1 second) in steps of 200 msec. Press E:
PROGRAM PANEL
-
time
003
006
25