Keypads Page; Led Keypads - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Ø Warning BPI Input Expander = Lost Input Ex-
1
pander
Ø Warning Keypads = Lost Keypad
Ø Warning Output Expanders = Lost Output Ex-
1
pander
Ø Warning Power Stations = Lost Power Station
+
The event will be recorded in the Log (refer to
ID.TYPE for the BPI Device Lost event).
No. This field shows the Identifier number of the device.
The Identifier number of a BPI Device is also the device Ad-
dress (refer to "Assigning Addresses" under "Connecting
BPI Devices" in the "INSTALLATION" section).
Description This editable field (maximum 16 charac-
ters) is for the device label (e.g. Entrance, Kitchen,
etc.). This Description will identify the Device in all the
operations it is involved in.
n Keypads Page
The Keypads page will allow you to set up Keypads.
The Page layout is as follows.
+
For information regarding the ü, No. and Descrip-
tion parameters, refer to the "Configuration" section.
Enabled on Partitions Select the Keypad Partitions.
The Keypad will be able to control (Arm, Disarm, etc.)
ONLY the Enabled Partitions.
+
Keypads need not necessarily be enabled on Parti-
tions, and can be used for programming, viewing
and other non-command related purposes.
The Partitions button (bottom of the window) will allow
you to deselect the Partitions (None), select all the Par-
titions (All), or invert the current setting (Toggle).
Quick Arm Code Select the Code that will be used for
Quick Arming (refer to "Quick Arm" in the USER MANUAL).
Memo Keypads with this attribute will be able
to record and play back Voice Messages.
Quick viewing of Partition status If
option is enabled, it will be possible to view
the status of ALL the Keypad Partitions by
pressing the ON key (refer to "Fast Status
Enquiry" in the USER MANUAL).
+
If Partition Alarm or Tamper is present
the respective character will blink.
Alarm/Tamper Beep If this option is en-
abled, the Keypad will emit an audible signal
(beep), when Alarm or Tamper is detected on
any of its Partitions.
1 The M-IN/OUT Expander is seen as an Input Expander and/or as an Output Expander, depending on how it is
programmed (see "M-IN/OUT Programmable Input/Output Expander" in the "INSTALLATION" chapter).
32
Display Panel Alarm Memory If this option is enabled,
the a LED will signal the presence of Panel Alarm memory.
Display Partition Alarm Memory If this option is en-
abled, the a LED will signal the presence of Partition
Alarm and/or Tamper memory.
Also LED keypads provide the Display Panel Alarm
Memory and Display Partition Alarm Memory options.
Comp. EN50131 If this option is enabled, in standby
mode the keypad will hide the control unit and zone dis-
play status (this is necessary to achieve EN50131 cer-
tification). To display this information, you will have to
enter your own access code first. In the event of a mal-
function, indicator light G will be illuminated, but in or-
der to view malfunction information you will have to en-
ter your own access code.
Viewable Partitions Select the Partitions (1 through 32)
that will be shown on the Keypad concerned. At default,
the first eight characters on the second line of the dis-
play correspond to Partitions 1 through 8.
+
n LED Keypads
The LED Keypads page will allow you to set up LED
Keypads.
+
this
Figure 25 Keypads page
The Partitions must be selected in successive or-
der, therefore, if Partition no. 5 is selected first, Par-
titions no. 1 through no. 4 cannot be selected.
For information regarding the ü, No. and Descrip-
tion parameters, refer to the "Configuration" section.